NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

Lab report, Week of 03/08/02, ATC World Trade Center

Machine-extracted title · confidence 44%

Summary of laboratory results and direct readings collected by ATC at WTC site, week of 03/08/02–03/15/02.

NYC-WTC_000361351–000361353
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Liberty Mutual.

Industrial Hygiene Measurements Summary for Week of 03/08/02 to03/15/02

Attached is a summary of the laboratory results reported and direct reading measurements completed during the week of March 8, 2002 to March 15, 2002. The air samples were collected and the measurements were made by ATC Associates at the World Trade Center site.

The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore the sampling device. Most of results have shown exposure levels to be below 50% of the shift adjusted occupational exposure limits. The exceptions were:

• Elevated quartz concentrations as follows: • 15833% of the shift adjusted OEL while drilling in WTC 6. • 512% and 221% of the shift adjusted OEL while drilling in WTC 6. • 358% of the shift adjusted OEL while using a jack hammer in WTC 6. • 50% and 58% of the shift adjusted OEL on a spotter in WTC 6.

• Elevated respirable dust concentrations as follows: • 667% of the shift adjusted OEL while drilling m WTC 6.

Elevated asbestos concentrations as follows: • 120% of the shift adjusted OEL while on an equipment (unspecified) operator at the WTC 4 site.

• Elevated diesel exhaust particulate concentrations as follows: • 119% of the shift adjusted OEL while torch cutting on surface. • 166% of the shift adjusted OEL on a laborer in the PATH tunnel.

• 8 hour equivalent time-weighted average noise levels above 90 dBA as follows: • 100 dBA on a driller at VI7. • 97 dBA while using an electric diamond saw to cut concrete • 95 dBA for a Brokk operator in WTC 6. ■94 for a driUer in WTC 6. • 93 dBA for an equipment operator in pit. • 93 dBA on spotter in WTC 6 • 91 dBA for a laborer in WTC 6. • 87 dBA for a dtiUer in WTC 6. • 85 dBA while using a saw to cut electrical cable.

The very high silica result on the drill operator is very unusual The IH technician’s field notes did not reveal anything unusual about this particular operation. Since all other quartz samples that have been collected on drill operators have been much lower than this, it is more likely that something went wrong with the sample than it is that this sample is representative of the exposure. Drill operators will continue to be monitored by air sampling. Attached is a list of other recent sihca samples for drill operators. The information on this hst indicates that sihca exposures to drill

CITY_21MC1OO_OO2845736

NYC-WTC_000361351

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361351Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →