NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 3 pages

WTC 5 mold remediation memo, Apr 2002

Machine-extracted title · confidence 40%

Mold assessment memo with recommended remediation controls following ATC sampling.

NYC-WTC_000361320–000361322
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

VVTC IH OPERATIONS Date: 04/25/02 To: Bruce Rottner - DDC CC: Bob Adams - DDC Ray Master - Bovis Lend Lease. LMB John Rabovsky - LMG Vic Hillman - LMG Mike Ramsey-LMG Mike Donavan - ATC From: Donald A. Weber RE: WTC 5 Mold Assessment - Non Viable (spore) Results

Bruce,

Mike Donovan of ATC Associates and I conducted an assessment of mold on 4/23/02. We collected samples in two areas of WTC 5 B4, in the NE stairway leading from the loading dock and outside at the ATC trailer. We collected samples for non-viable airborne fungi, viable airborne fungi and bacteria and bulk samples for microbial analysis.

Analytical results for fungal spores arc attached . The balance of the results should be available within several days due to the need for culturing and “growing” the samples The results reported here quantify total fungal spores and provide general identification guidance. As a result of our observations and attached sample results the following recommendation is submitted:

IH02-12: Management and Remediation of WTC 5 Mold

Reduce exposures to mold to the lowest feasible level. This should be accomplished by implementing the following controls at a minimum:

• Upgrade barriers to airtight seals in stairwells leading to WTCS B4.

• Label these entry points as permit required confined spaces (based on restricted means of egress and acute hazard presented by very high bioaerosol levels)..

• Manage entry into the space under the sites PRCS program.

• Enforce minimum PPE guidelines previously recommended including full face respirators witli tri­ combination filters, full body coverings- Tyvek suits, protective gloves and shoe coverings.

• Remove entrant protective clothing prior to leaving the stairwell area to minimize contamination drag out Respiratory protection should only be removed when outside of the B2 area.

1

CITY_21MC100_006534941

NYC-WTC_000361320

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000361320Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →