NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
27 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗Law Department Appendix K: indoor air and dust test results after WTC collapse.
NYC-WTC_000360376–000360381OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Table K-4: Indoor Air Test Results from October 23,2001 "pcMAnaiysiT' TEM Analysis Sample Sample Volume f/mm2 s=.5-5 s>5 Address ID _J2i_ f/cc 12] f/cc s/mm2 _J2L- 100 Church St (front of 1927/8) 11931 2400 0.002 9.55 na <20 0 0 100 Church St (Lobby) 11932 2400 0.002 11.46 na <20 0 0 100 Church St (1909/1910) 11933 2160 0.003 15.92 na <20 0 0 100 Church St (1902/1903) 11934 2400 0001 7.64 na <20 0 0 100 Church St (Alley 1960) 11935 2400 <0.001 <7 na <20 0 0 100 Church St (Alley 1941) 11936 2400 <0.001 <7 na <20 0 0 100 Church St (1935/1937) 11937 2400 0.004 21.66 na <20 0 0 100 Church St (1835/1837) 11938 2400 <0.001 <7 na <20 0 0 100 Church St (18FL-SW corner) 11939 2400 <0.001 <7 na <20 0 0 100 Church St (IS'” main lobby) 11940 2400 0.005 30.57 na <20 0 0
KEY: np = sample volume not provided on data sheets. na= not analyzed for this metric.
NOTES: [1] = sample volume for TEM (AHERA method) is 1200 liters for 25 mm filter [2] = fibers per millimeter squared [3] = structures equal to or greater than 0.5 micrometers and less than or equal to 5 micrometers in length [4] = structures greater than 5 micrometers in length
General Services Administration Monitoring of Federal Buildings
From September 13, 2001, through January 2, 2002, the General Services Administration, which is responsible for Federal building management, arranged for indoor environmental testing at Federal buildings located at 290 Broadway, 26 Federal Plaza, 201 Varick Street, and 1 Bowling Green. Over 100 air samples were analyzed and all samples were below the AHERA standard of 70 s/mm2. All but four air samples analyzed by TEM were non-detect for asbestos. The four samples that detected asbestos all occurred between September 13 and September 19, 2001. Two samples showed 25 s/mm2 and two samples could not be analyzed because the filters were overloaded. The only testing for asbestos in dust was conducted on September 14,2001. Three dust samples collected in the lobby of 290 Broadway and two collected outside the building on September 13, 2001, showed the presence of chrysotile asbestos by TEM analysis. The results for these tests only reported whether asbestos was present or not, not the percentage of asbestos in the sample. Table K-5 through K-7 provide more information on the results of indoor testing of Federal buildings.
I 1
96 Report No. 2003-P-00012
NYC-WTC_000360379
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
27 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
14 shared non-person entities · 1 shared topics · similarity 0.967
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243668
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
15 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243806
Environmental assessment for 100 Church Street prepared by TRC Engineers.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243532
EIA report for 100 Church Street preparation by TRC Engineers.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000176247
Comprehensive environmental assessment report prepared by TRC Engineers for the New York City Law Department.
19 shared non-person entities · 1 shared topics · similarity 0.963
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000149432
DEP asbestos project notification form and inspection report dated December 12, 2002.
15 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000151361
A letter defending the validity of DEP and contractor data used to clear residential units at 114 Liberty Street for re-occupancy.
11 shared non-person entities · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320385
Oldraft report for World Trade Center background study prepared for FEMA, EPA Region 2.
15 shared non-person entities · 1 shared topics · similarity 0.962
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000145345
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
Similarity score 0.993 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000145510
Notice from NYC Law Department instructing staff to preserve World Trade Center documents for potential legal actions.
Similarity score 0.987 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000318340
Office findings on EPA response to World Trade Center issues; August 2003.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
Similar indexed content
NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similar indexed content
NYC-WTC_000243668
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
Similar indexed content
NYC-WTC_000145869
Interim final report from EPA Region 2 detailing a background study of environmental conditions at the World Trade Center site.
Similar indexed content
EIA report for Law Department project at 100 Church Street by TRC.
Similar indexed content