NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 4 pages

IAQ report, PS 89M, March 2002

Machine-extracted title · confidence 25%

ATC memo transmitting IAQ measurements for PS 89M dated March 4, 2002.

NYC-WTC_000360262–000360265
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

03/04/2002 11:35 FAX 212 353 8306 ATC @005

Mr. Bernard P. Orlan March 4, 2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATC Project No, 15-19125-0297 individuals and children. The outdoor respirable particulate concentration measurements ranged from 28 to 32 pg/m^ with an average of 21 |4g/m^.

* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.

TVOC Concenirgrians

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment. • No smoke odor was detected in the building • The interior of the building appeai'ed clean and free of dust and debris.

FINDINGS

Based on the real-time measurements, the following findings are presented:

L Concentrations of respirable particulates, CO, and TVOCs were below the applicable standar ds and guidelines. 2. One (1) of the CO2 measurements was above the ASHRAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. 3. All of the indoor measurements of relative humidity were below the ASHRAE recoimnended range of 30 to 60 percent for occupant comfort. 4. One (1) indoor temperature measurements was below the range of 68 to 75“F (at 50 percent relative humidity) as recommended by the ASHRAE Standard 55-1992 during the heating season (wintertime conditions).

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 336 or 212.

Sincerely, Reviewed by: A TCASSOC/A TES INC.

0^^ Senior Project Manager James R. Cohn, CIH, CSP Regional Manager Industrial Hygiene Division Attachment

CITY_21MC100_009253543

NYC-WTC_000360265

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360265Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →