03/04/2002 11:35 FAX 212 353 8306 ATC @003

Mr. Bernard P. Orlan March 4,2002 Indoor Air Quality .Assessment Page 2 F, S. 89M ATCProiectNo, 15-19125-0297 sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The infonnation presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory standai'ds for indoor air quality in non-wdustnal buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in tire following publications:

Ventilation for Acceptable Indoor Air Quality (ASHHAE 62^1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA),

Table 1 lists target guidelines for the parameters that ATC evaluated during tins investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLE 1 TARGET GUIDELINES TOR INDOOR AIR QUALITY PARAMETERS EVALUATED liiK® H!? W Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2)____________ above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (pr/'m^) 24-hour average 40 ftg/m^ 24-hour av^age USEPA - Recommendation for children / sensitive individuals Temperature Summer; 73-79’F at 50% RH ASHRAE 55 Winter; 68-75°F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55 Total Volatile Organic Compounds 1 PP™ AIHA (TVOC) USEPA = United States Environraental Protection Agency NPAAQS “National Primary .Ambient-Air Quality Standard AIHA = American Industrial Hygiene Association

CITY_21MC100_009253541

NYC-WTC_000360263

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360263Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →