IAQ indoor air quality report, P.S. 89M, Apr 2002

Machine-extracted title · confidence 42%

ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.

NYC-WTC_000360042–000360045
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

05/01/2002 11:03 FAX 212 353 8306 ATC 0005

Mr. Bernard P, Orlan May 1,2002 Indoor Air Quality Assessment Page 4 P. S. 89M ATCPrpiectNoa5-19125-0297

* The measurements made during this assessment were instantaneous readings, tire NPAAQS is a 24-hour average.

TVOC Concentrations

TVOCs were not detected anywhere inside the building (0.0 ppm). The outdoor TVOC concentration was also 0.0 ppm.

OBSERVATIONS

During this assessment, ATC noted the following: • The school building was occupied at the time of the assessment. • No smoke odor was detected in the building • The interior of the building appeared clean and free of dust and debris

EINPINGS

Based on the real-time measurements, the following findings arc presented;

1, Concentrations of CO2, CO, and TVOCs were below applicable standards and guidelines. 2. All of the indoor measurements for temperature were below the range of 73 to 79®F (at 50 percent relative humidity) as recommended by the ASHRAJE Standard 55-1992 during the summer season. 3. Thirty-nine (39) of the indoor measurements for relative humidify were below the ASHRAE- recommended range of 30 to 60 percent for occupant comfort. 4. All of the indoor measurements were below die NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2,5 micrometers or less in aerodynamic diameter and the USEPA recommended concentration of 40 pg/m^ for sensitive individuals and children. Both outdoor readings were above the USEPA recommended concentration of 40 pg/m3 for sensitive individuals and children.

It is our pleasure to provide these indoor air quality services to the New York City Board of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.

Sincerely, ATC/tSSOCLiT£S INC. Reviewed by:

Viannis Efstathiou James R. Cohn, CIH, CSP Senior Project Manager Regional Manager. Industrial Hygiene Division

Attachment

CITY_21MC100_012158093

NYC-WTC_000360045

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000360045Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →