0g/^/2«02 J^.3 FAX 212 353 8306 ATC ®OO2/O14

600 West Cummings Park, Suite 6500 Woburn, Massachusetts 01801-6360 www.atc-enviro.com 781,932.9400 Fax 781.932.6211 ASSOCIATES INC.

June 27,2002 i Mf. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 28-11 Queens Plaza Nortlr Long Island City, NY 11101 -4008

Re: Indoor Air Quality Assessment l’.S. 89M 201 Warren Street New York, New York 10282 ATC Project No. 15-19125-0297

Dear Mr Orlan:

ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on June 26,2002, at the referenced school. Tire New York City Board of Education (BOE) requested these measurements to evaluate air quality in tire school building.

SCOPE OF WORK

ATC conducted this evaluation to assess the basic parameters of temperature, relative humidity, carbon dioxide (CO,) and carbon monoxide (CO).

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactLued by TSI, Inc.

ATC measured concentrations of respirable particulates (PM2.5) with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc.

ATC measured concentrations of Total Volatile Organic Compounds (TVOCs) using a RAE Systems, Inc. MiniRAE® photoionization detector (PED).

Mr. Kevin Fitzpatrick, Environmental Technician, of ATC’s New York City office, conducted the assessment.

ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

The assessment was pcrforroed consistent witli generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality parameters and sampling and analytical accuracy. The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The information

CITY_21MC100_012158048

NYC-WTC_000359998

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359998Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →