NYC-WTC_000340679
ATC May 7, 2002 letter to BOE regarding IAQ measurements at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗IAQ field report for PS 89M with date June 2002 noted.
NYC-WTC_000359970–000359973OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
06/20/2002 13:17 FAX 212 353 8306 ATC @003/014
Mr. Bernard P. Orlan June 20, 2002 Indoor Air Quality Assessment Page 2 t
P. S. 89M___________ ATC Project No. 15-19125-0297 presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.
I EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications;
Ventilalion for Acceptable Indoor Air Quality (ASHRA£ 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions for Human Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide to Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).
Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLE 1 TARGET GUIPELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED
Carbon Dioxide <700 parts per million (ppm) ASHRAE62 (CO2)______________ above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA MPAAQS Particulates (PM?,5) of air (pg/m^) 24-hour average 40 ug/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer; 73-79'T at 50% RH ASHRAE 55 Winter; 68-75’F at 50% RH Relative Humidity 30-60% ASHRAE55 Total Volatile Organic Compounds 1 pptxi AIHA (TVOC) USEPA = United States Environmental Protection Agency NP AAQS = National Primary Ambient-Air Quality Standard AULA. = American Industrial Hygiene Association
CITY_21MC100_012158021
NYC-WTC_000359971
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000340679
ATC May 7, 2002 letter to BOE regarding IAQ measurements at PS 89M.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
13 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340449
ATC report of indoor air quality for P.S. 89M, 201 Warren Street, Jun 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359998
ATC Associates reports indoor air quality measurements at P.S. 89M, NYC, June 2002.
14 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313917
ATC indoor air quality measurements collected June 20, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000211036
Report of indoor air quality measurements conducted at P.S. 89M on June 19, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313905
ATC IAQ measurements for PS 89M conducted June 19, 2002 per BOE.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313893
ATC IAQ measurements collected June 18, 2002 at PS 89M per BOE request.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000313952
ATC report of IAQ measurements at P.S. 89M, June 24, 2002, requested by NYC BOE.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369765
ATC IAQ measurements at PS 89M for BOE, May 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000370101
ATC IAQ report for PS 89M dated June 21, 2002.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000369326
IAQ measurements collected June 20, 2002 for PS 89M.
14 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000340627
ATC May 16, 2002 memo re IAQ measurements at PS 89M.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340699
ATC IAQ measurements conducted May 2, 2002 for P.S. 89M, NYC DOE.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360010
ATC provides indoor air quality measurements report for June 2002 at P.S. 89M, New York City.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000220664
Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 23, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000205292
Report from ATC Associates detailing indoor air quality measurements collected on May 3, 2002, at PS 89M school building.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340449
ATC report of indoor air quality for P.S. 89M, 201 Warren Street, Jun 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000340679
ATC May 7, 2002 letter to BOE regarding IAQ measurements at PS 89M.
Similar indexed content
NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
Similar indexed content
NYC-WTC_000340449
ATC report of indoor air quality for P.S. 89M, 201 Warren Street, Jun 2002.
Similar indexed content
NYC-WTC_000359998
ATC Associates reports indoor air quality measurements at P.S. 89M, NYC, June 2002.
Similar indexed content
NYC-WTC_000313917
ATC indoor air quality measurements collected June 20, 2002 for PS 89M.
Similar indexed content