05/03/2002 12:56 FAX 212 353 8306 ATC ®003

Mr. Bernard P. Orlan May 3,2002 Indoor Air Quality Assessment Page 2 P. S. 89M_________________________________________ ATC Project No. 15-19125-02_97 presented in this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

EVALUATION CRITERIA

Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:

Ventilation for Acceptable /ndoor Air Quality (AS1£KAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditionsforliuman Occupancy (ASHRAE 5^-1992); industrial Hygienists Guide io Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AIHA).

Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.

TABLEI TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED a

Carbon Dioxide ■M _____ __________________ I VisgaWwftWWrMw MW ' <700 parts per million (ppm) ASHRAE62 (CO2) _________ above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO)_____________ USEPA NPAAQS) Respirable 65 micrograms per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (pg/m^) 24-hour average 40 gg/m^ 24-hour average USEPA - Recommendation for children / sensitive individuals Temperature Summer; 73-79’F at 50% RH ASHRAE 55 Winter: 68-75°F at 50% RH Relative Humidity 30-60% A$HRAE55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmental Protection Agency NPAAQS = National Primary Airibicnt-Aii Quality Standard AIHA = American Industrial Hygiene Association

CITY_21MC1OO_OO9261675 NYC-WTC_000340700

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000340700Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

IAQ report for PS 89M, Apr 2002 · page 2

NYC-WTC_000220668

Formal indoor air quality assessment report submitted to the Board of Education regarding measurements taken at PS 89M on April 25, 2002.

Similarity score 0.997 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000199015

Cover letter from ATC Associates submitting indoor air quality measurement results for PS89M collected on May 16, 2002.

Similar indexed content

Compare copies and versions →