NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 5 pages

Indoor air quality report, PS 89M, Feb 2002

Machine-extracted title · confidence 32%

IAQ report from ATC for PS 89M; date February 2002 noted.

NYC-WTC_000359918–000359922
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

02/05/2002 11:00 FAX 212 353 8306 ATC @002

104 East 25th S Ngw York, New York 100K www.atc-enviro.corT 212.353.B28C Fax 212.353.830e ASSOCIATES INC.

Febmaiy 5, 2002

Mr. Bernard P. Orlan Director, Environmental Health & Safety New York City Board of Education 2S-11 Queens Plaza North Long Island City, NY 11101-4008

Re: Indoor Air Quality Assessment P.S. 89M ATC Project No. 15-19125-0297

Dear Mr. Ori an:

ATC Associates Inc. (ATC) is pleased to provide this report of indoor air quality (lAQ) measurements collected on February 4,2002, at the referenced school. The New York City Board of Education (BOE) requested these measurements to evaluate air quality in the school building prior to re-occupancy.

SCOPE OF WORK

ATC conducted this evaluation to assess tire basic parameters of temperature, relative humidiry, carbon dioxide (CO,) and carbon monoxide (CO).

ATC measured temperature, relative humidity, CO, and CO with a Q-Trak® Model 8551, manufactured by TSI, Inc.

ATC measured concentrations of respirable particulates (PM2.5) with a Dust-Trak® Aerosol Monitor Model 8520, manufactured by TSI, Inc,

ATC measured concentrations of TVOCs using a RAE Systems, Inc. MiniRAP.® photo ionization detector (PID).

Mr. Jirai-ny Choy, Industrial Hygienist of ATC’s New York City office, conducted the assessment.

ATC’s findings and conclusions are based on a visual inspection, real-time environmental measurements and conditions present in the school at the time of the assessment.

CITY_21MC100_012157991

NYC-WTC_000359918

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359918Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

IAQ memo, PS 89M, Jan 2002

NYC-WTC_000400632

Report of indoor air quality measurements at PS 89M; January 28, 2002.

Similar indexed content

Compare copies and versions →