02/18/2002 09:02 FAX 212 353 8306 ATC @003/010
Mr. Bernard P. Orlan February 18, 2002 Indoor Air Quality Assessment Page 2 P. S. 150M____ ATC Project No. 15-19125-0289
The assessment was performed consistent with generally accepted indoor air quality assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in indoor air quality parameters and sampling and analytical accuracy. The results of the sampling represent conditions found on tire dates of the survey and may not represent conditions found at other times. The information presented in this report should be used by the BOE as a guide to assess the need tor further improvements in current indoor air quality control activities.
EVALUATION CRITERIA
Currently, there are no regulatory standards for indoor air quality in non-industrial buildings, such as offices and schools. For the real-time data collected, ATC uses the commonly accepted guidelines cited in the following publications:
Ventilation for Accsplable Indoor Air Quality (ASHRAE 62-1999), American Society of Heating, Refrigerating, and Air-Conditioning Engineers (ASHRAE); Thermal Environmental Conditions fur Hu/nan Occupancy (ASHRAE 55-1992); Industrial Hygienists Guide tc Indoor Air Quality Investigations (1993), American Industrial Hygiene Association (AHTA).
Table 1 lists target guidelines for the parameters that ATC evaluated during this investigation. Meeting one, some, or all of the listed values does not assure that acceptable indoor air quality will be achieved at all times.
TABLE 1 TARGET GUIDELINES FOR INDOOR AIR QUALITY PARAMETERS EVALUATED SWMwiWww®
Carbon Dioxide <700 parts per million (ppm) ASHRAE 62 (CO2) above background level Carbon Monoxide 9 ppm ASHRAE 62 (adopted from (CO) USEPA NPAAQS) Respirable 65 Tfiicrogrems per cubic meter USEPA NPAAQS Particulates (PM2.5) of air (Mg/m3) 24-hour average 40 24-hour average USEPA - Recommendation for cluldren / sensitive individuals Temperature Summer: 73-79°F at 50% RH ASHRAE 55 Winter; 6S-75“F at 50% RH Relative Humidity 30 - 60 % ASHRAE 55 Total Volatile Organic Compounds 1 ppm AIHA (TVOC) USEPA = United States Environmeiitsl Protection Agency NPAAQS = National Primary Ambient-Air Quality Standard AIHA = American Industrial Hygiene Associaiion
CITY_21MC100_009253102 NYC-WTC_000359789
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000359796
Memo re: PS 89M IAQ measurements and project details.
11 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360230
ATC memo/letter transmitting IAQ measurements for PS 89M, March 2002.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359735
Fax cover and correspondence about PS 89M sampling at 201 Warren Street, Jan 2002.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360054
ATC Indoor Air Quality report for April 2002 measurements at P.S. 89M, NYC.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000289354
Report of indoor air quality measurements conducted February 8, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340553
ATC report of indoor air quality at P.S. 89M, Warren Street, May 2002.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000410459
ATC IAQ report for PS 150M; measurements conducted Feb 14, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340521
ATC report of indoor air quality measurements at P.S. 89M, June 2002.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000209128
ATC Associates formal letter submitting indoor air quality measurement reports for P.S. 89M to the Board of Education.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340627
ATC May 16, 2002 memo re IAQ measurements at PS 89M.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000340497
ATC report of indoor air quality measurements at P.S. 89M, early June 2002.
11 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000410459
ATC IAQ report for PS 150M; measurements conducted Feb 14, 2002.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236967
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360230
ATC memo/letter transmitting IAQ measurements for PS 89M, March 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000218435
ATC Associates submitted an indoor air quality measurement report for P.S. 234M collected on February 1, 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300655
ATC IAQ field report for PS 150M, Feb 2002.
Similarity score 0.996 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000359672
Memo/letter related to PS 89M environmental sampling at 201 Warren Street, Jan 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000359796
Memo re: PS 89M IAQ measurements and project details.
Similar indexed content
NYC-WTC_000360042
ATC prepares IAQ measurements report for April 29, 2002 at P.S. 89M, NYC.
Similar indexed content
NYC-WTC_000360230
ATC memo/letter transmitting IAQ measurements for PS 89M, March 2002.
Similar indexed content
NYC-WTC_000359735
Fax cover and correspondence about PS 89M sampling at 201 Warren Street, Jan 2002.
Similar indexed content
NYC-WTC_000360054
ATC Indoor Air Quality report for April 2002 measurements at P.S. 89M, NYC.
Similar indexed content