Mr. Bernard P. Orlan January 24, 2002 Indoor Air Quality Assessment Page 3 P, S. 89 (Manhattan) ATC Project No. 15-19125-0297
: i
real-Time Environmental Measurements
ATC collected eighty (80) sets of real-time environmental measurements consisting of seventy- six (76) from inside the school building and four (4) outdoors from the playground. All five floors of the school were surveyed. I’liese results are described below.
Field data sheds are found tn Attachment 1 Readings began at 8:00 A.M. and concluded after 2:30 P.M.
Tsmperett'urs
Indoor dry bulb temperature measurements ranged from 68.0 ®F to 76.0 ®F. Two (2) measurements were above the range of 68 to 75°F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the heating season (wintertime conditions). The outdoor temperature measurements at the playground ranged from 49.1 to 52.0 °F.
Re/ative Humidity
The relative humidity indoors ranged from 18.2 percent to 40.8 percent. Twenty (20) measurements were within the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. All other measurements were below the recommended range. The outdoor relative humidity ranged from 25.0 to 36.1 percent.
Catbon Dioxidi.' Cimeeniralion
Carbon dioxide concentrations indoors ranged from 480 ppm to 1150 ppin. All CO2 measurements were below the ASH RAE Standard 62-1999 recommended maximum concentration of <700 ppm above the background level. The outdoor (background) COo concentrations ranged 458 to 475 ppm. Therefore, the maximum acceptable level of CO2 this location was 1175 ppm (background level -1- 700 ppm). Levels above the recommended maximum do not indicate a health risk. Carbon dioxide measurements are used as an indicator of available outdoor air. The primary source of COo indoors is occupant respiration. The school building during ATC’s assessment was not occupied.
Carbon Monoxide Concentration
Carbon monoxide concentrations indoors were 0 ppm for all readings. These concentrations were below the NPAAQS/ASIIRAE guideline of 9 ppm. The outdoor CO concentration was 0 ppm.
Re.vpirable Pa]''ticitlate.}i ('PM2_^
Respirable particulate concentrations* indoors ranged between 8 gg/m^ to 17 pg/m^. All measurements were below the NPAAQS of 65 gg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter as well as the USEPA
P0 397d T:TD±V Z2.8028e2TZ TS :60 Z00Z/SZ/T0
CITY_21MC100_012157826
NYC-WTC_000359709
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000384033
ATC report of IAQ measurements collected January 23, 2002 at PS 89M for NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245343
ATC Associates reports IAQ measurements conducted at the referenced school for the NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245303
IAQ measurements at P.S. 89M; January 18, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.997
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400594
Report of indoor air quality measurements at PS 89M for BOE project.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245331
ATC Associates provides IAQ measurement results for P.S. 89M requested by NYC BOE.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000396289
ATC IAQ measurements at PS 234M, January 2002.
11 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000187673
Cover letter from ATC Associates submitting an indoor air quality assessment report for PS150M collected on March 19, 2002.
8 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000314771
Indoor air quality measurements collected March 26, 2002 at PS 234M.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300802
IAQ measurements report for PS 150M prior to re-occupancy, March 2002.
10 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000384064
ATC IAQ measurements at P.S. 89M for NYC BOE; report dated Jan 29, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000236958
Letter from ATC Associates to NYC Board of Education reporting indoor air quality measurements at P.S. 89M collected on January 18, 2002.
12 shared non-person entities · 1 shared topics · similarity 0.996
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000245303
IAQ measurements at P.S. 89M; January 18, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326012
IAQ report for S-PS 89M, January 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
Similarity score 0.995 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245343
ATC Associates reports IAQ measurements conducted at the referenced school for the NYC BOE.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400582
Report of IAQ measurements at PS 89M, NYC BOE building, January 2002.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000245331
ATC Associates provides IAQ measurement results for P.S. 89M requested by NYC BOE.
Similarity score 0.994 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000384033
ATC report of IAQ measurements collected January 23, 2002 at PS 89M for NYC BOE.
Similar indexed content
NYC-WTC_000245343
ATC Associates reports IAQ measurements conducted at the referenced school for the NYC BOE.
Similar indexed content
NYC-WTC_000245303
IAQ measurements at P.S. 89M; January 18, 2002.
Similar indexed content
NYC-WTC_000226873
ATC Associates report on indoor air quality measurements collected at P.S. 89M on January 17, 2002.
Similar indexed content
NYC-WTC_000400594
Report of indoor air quality measurements at PS 89M for BOE project.
Similar indexed content