NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 10 pages

FEMA contract work summary, PS 833

Machine-extracted title · confidence 45%

FEMA disaster-related air/water/dust testing at PS 833; project numbers and period covered.

NYC-WTC_000359507–000359516
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Finance Page 6 of 8 ’

2. Lead specific cleaner shall be utilized. 3. Re-test said areas following clean up. 4. Floor mats and/or other dust control devises shall be placed at points of entry. Actions 1,2 and 3 shall be repeated until satisfactory results are obtained.

SILICA AIR SAMPLES

• First floor lobby - one sample. • Fifth floor hallway, near elevators - one sample. • Tenth floor hallway, near staircase B - one sample.

All sample collected shall be analyzed utilizing the NIOSH 7500 method for respirable silica.

Since, there are no regulatory standards for Mineral Dust in non-industrial buildings, such as offices and schools at this time, the OSHA standard 1910.1000 TABLE Z-3 shall be utilized (per the request of PA consultant).

Results from samples collected shall be reported to BOE, UFT, School Principal and the PA consultant within 72 hours from the collection day.

In the event that unsatisfactory results are obtained, the following actions are to be implemented:

1. Perform general dust clean up of all areas/classrooms with unsatisfactory results. 2. Re-test said areas following clean up. 3. Floor mats and/or other dust control devises shall be placed at points of entry.

Actions 1,2 shall be repeated until satisfactory results are obtained.

DIOXIN WIPE SAMPLES

• First floor lobby - one sample. • Fifth floor hallway, near elevators - one sample. • Tenth floor hallway, near staircase B - one sample.

All sample collected shall be analyzed utilizing the EPA 8290 PCDD/DF Dioxin Furan method.

c Results from samples collected shall be reported to BOE, UFT, School Principal and the PA CD E consultant in 15 business days from the day of sampling. 3 o o Q In the event that any one sample result is unsatisfactory BOE will immediately notify the TO UFT, the school principal, the school custodian and the PA consultant. The said parties will ■c o assess the situation and implement the appropriate response action(s). Q_ co o o PCB WIPE SAMPLES o Z o 3 D. o'

O) O 6 z z

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359514Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

PS 89M lab report, 2002 · Box unavailable

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

18 shared non-person entities · 1 shared topics · similarity 0.973

machine-extracted · confidence unavailable · Check page ↗

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PS 89M lab report, 2002 · page 8

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similarity score 0.974 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

PS 89M lab report, 2002

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similar indexed content

NYC-WTC_000385892

Ambient air protocol for H.S. Economics and Finance following WTC cleanup.

Similar indexed content

NYC-WTC_000385905

Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.

Similar indexed content

Compare copies and versions →