AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.3. of Economics and Finance Page 4 of 3 -
In the event, that real-time measurements of respirable particulates exceed the cited Target
Guidelines. BOE will immediately notify the UFT. the school principal, the school custodian
and the PA consultant. The said parties will assess the situation and implement the
appropriate response action(s).
In the event, that CO inside the school measured above the cited Target Guidelines (9ppm).
BOE will immediately notify the UFT. the school principal, the school custodian and the PA
consultant. The said parties will assess the situation and implement the appropriate response
action(s).
In the event that real-time measurement(s) of CO inside the school is/are greater than 5ppm
and less than 9ppm. BOE will identify the source and assess the situation.
In the event that real-time measurement(s) of TVOC inside the school is/are above the cited
Target Guidelines (1ppm). BOE will immediately notify the UFT. the school principal, the
school custodian and the PA consultant. The said parties will assess the situation and
implement the appropriate response action(s).
In the event that real-time measurement(s) of 0.5 ppm of TVOC are obtained inside the
school BOE will notify the UFT. the school principal, the school custodian and the PA
consultant. The said parties will assess the situation and implement the appropriate response
action (s)
ADDITIONAL TESTING
In addition to the above, once per week, preferably on Thursday, sampling settled dust for
fiberglass, lead, and silica; wipe sampling for dioxin and PCB and air sampling, for heavy
metals, and TVOCs shall be performed as follows:
SETTLED FIBERGLASS
• First floor lobby outside Auditorium - one sample.
Cafeteria - one sample.
• Auditorium - one sample
Two random classrooms - one sample from each classroom
• Third floor Hallway - one sample
• Fifth floor Hallway - one sample
c
<D
E • Seventh floor Hallway - one sample
o
o
Q • Ninth floor Hallway - one sample CM
TO
t 55
O
CL Dust bulk samples will be collected at the aforementioned locations and analyzed via
co
O Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not o
S o
o