AMBIENT AIR AND DUST SAMPLING PROTOCOL for H.S. of Economics and Finance Page 4 of 8

In the event, that real-time measurements of respirable particulates exceed the cited Target Guidelines, BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event, that CO inside the school measured above the cited Target Guidelines (9ppm). BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event that real-time measurement(s) of CO inside the school is/are greater than 5ppm and less than 9ppm, BOE will identify the source and assess the situation.

In the event that real-time measurement(s) of TVOC inside the school is/are above the cited Target Guidelines (1 ppm), BOE will immediately notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s).

In the event that real-time measurement(s) of 0.5 ppm of TVOC are obtained inside the school BOE will notify the UFT, the school principal, the school custodian and the PA consultant. The said parties will assess the situation and implement the appropriate response action(s)

ADDITIONAL TESTING

In addition to the above, once per week, preferably on Thursday, sampling settled dust for fiberglass, lead, and silica; wipe sampling for dioxin and PCB and air sampling, for heavy metals, and TVOCs shall be performed as follows:

SETTLED FIBERGLASS

• First floor lobby outside Auditorium - one sample.

Cafeteria - one sample.

• Auditorium - one sample

• Two random classrooms - one sample from each ciassroom

• Third floor Hallway - one sample

• Fifth floor Hallway - one sample

• Seventh floor Hallway - one sample

• Ninth floor Hallway - one sample

Dust bulk samples will be collected at the aforementioned locations and analyzed via Polarized Light Microscopy (PLM). In the event that in any of the above locations there is not

CITY_21MC100_003267180

NYC-WTC_000324138

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000324138Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

PS 89M lab report, 2002 · page 6

NYC-WTC_000250241

Laboratory report page with OCR-garbled content; appears to be environmental test results related to PS 89M.

Similarity score 0.998 (not a probability)

machine-extracted · confidence unavailable · Check page ↗

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000385905

Draft protocol for ambient air and dust sampling for asbestos at a NYC high school.

Similar indexed content

NYC-WTC_000385892

Ambient air protocol for H.S. Economics and Finance following WTC cleanup.

Similar indexed content

Compare copies and versions →