OSHA sampling results summary, asbestos

Machine-extracted title · confidence 37%

OSHA asbestos sampling results summary for 2002 rubble-pile and adjacent areas.

NYC-WTC_000359469–000359471
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

OSHA SAMPLING RESULTS SUMMARY AS OF 2/13/02

Asbcsios; A total of 1027 samples (excluding bulk and blank samples) for asbesics have been taken. From 9/13 -9/21, 177 samples were taken in the financial district. They were taken on OSHA personnel as they walked within certain predetermined zones. Results revealed asbestos concentrations ranging from ND (none detected) to .037 f'ce., well beiow OSH.'f’s permissible exposure limit (PEL) of 0.1 f/cc. After 9/21, sampling focused on the rubble pile and those workers working on or immediately ne.xt to it. 139 of the samples analyzed exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discriminating counting methods and/'or TEM analysis, the number of asbestos fibers found dropped dramatically to beiow detectable levels or well below .1 f/cc.

Carbon Monoxide: A total of 109 personal samples of workers on the rubble pile showed results ranging from 1 ppm to 34 ppm which are well below the OSHA permissible exposure limit of 50 PPM.

Noise; OSHA is monitoring the noise exposures of employees who perform (or work near) noisy operations such as jack hammerinc and drilling. To date the 95 samples collected indicate that employee noise exposures range from 75.7 dB.A to 94.5 dBA. One personal sample and one area sample taken durins core drilling operations have exceeded the applicable permissible exposure limit of 90 dBA. Accordingly, OSHA continues to recommend the use of appropriate hearing protection in noisy operations.

Total Dust (PNOR) A total of 141 samples (excluding bulk and blank samples) for total dust in and around the rubble pile were taken. 5 samples were found to be in excess of the PEL for Total dust (15mg/m3). The highest exposure was found on one operator who was exposed at approximately 4.PEL. Respirable Siiica; Tlie ox'cnvhclming majority of 674 silica samples (excluding bulk and blank samples) show no delectable levels of airborne silica. However, 41 exposures exceeded the PEL. The hiuliest sample result was approximately twentv-ont times the OSH.A iimil (jack hammerins concrete 16 feet below Grade). The other elevated exposures were approximately one to fourteen times the OSHA limit. These exposures Occurred during: 1) pre-drilling /slurry wall 2) jack hammerinc, 3) rubble removal and loading operations near the Winter Garden; 4) during the breaking up of concrete in the pit; 5) while

Page 1 of 3

This Document is a duplicate created by the WTC Unit of the New York City Law Department

CITY_21MC100_010405079 NYC-WTC_000359469

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359469Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →