Asbestos in Air analysis report, Pier 25

Machine-extracted title · confidence 32%

Analysis of air samples for asbestos at Stuyvesant High School project site, Pier 25.

NYC-WTC_000359275
Page image
Scanned page image, NYC-WTC_000359275
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36th Street

1^^ Long Island City NewYork, 11106 Tel: 718)729-1997 Fax: 718)729-1876 ANALYSIS REPORT ASBESTOS IN AIR Transmission Electron Microscopy

CLIENT: Department of Design and Construction - 30-30 I honison Avenue, Long Island City, NY 11101 PROJECT ADDRESS: Stuyvesant H.S., 345 Chambers St., NY, NY 10282 Pier #25 Lab ID# Client Sample Location Volume Grid Kilter Analytical Asbestos Asbestos -Structures Delected Structure Density Structure Sample (liters) Openings Area Sensitivity lypel.s) (microns) (struc/mm^) Concentration ID# Examined (mm"! (struct/cc air) Total (slruc/cc) O5-5.U >5.0 Total Total TO20123B-O1 North Exit of Siu)vesant ILS. 1800 6 385 0.0043 ND 0 0 0 <2000 <0.0043

TO2O123B«O2 North West She 1800 6 385 0.0043 ND 0 0 0 <2000 <00043

Area Analyzed: 0 0600 mm’ Dale Received: 01/23/02

a- Grid Opening Area: 0 010 mm’ Date Analyzed; 01/23/02 O Date Collected: 01/21/02(07:00-17:00> Dale of Report: 01/25/02 H H Analysl; Lab Manager: K I David Chen David Chen Analysis performed according to AHERA Method (EPA 40 CFR Pan 763 - Appendix A).Samples will be stored for ninety (90) days and then returned to the client upon request. Sample volume is below recommended limit of the method AIHA#: 100269 MSn-NVLAP#: 102047 NYS-DOII ELAP«; 1I27J o o I o

hJ Cn O -J

NYC-WTC_000359275

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359275Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Buildings in this record

Machine-extracted building matches; verify each source. Buildings, never households.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →