Asbestos in Air analysis report, Stuyvesant HS

Machine-extracted title · confidence 45%

Lab ID and sample data for asbestos in air at Stuyvesant H.S., Pier 25.

NYC-WTC_000359163
Page image
Scanned page image, NYC-WTC_000359163
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

KAM CONSULTANTS 35-40 36lh Street

Itano. Long Island City New York, 11106 Tel: (716 729-1997 Fax: (718 729-1876 ANALYSIS REPORT ASBESTOS IN AIR Transmission Electron Microscopy

CLIENT: Department of Design and Construction - 30-30 Thomson Avenue, Long Island City, NY 11101 PROJECT ADDRESS: Stuyvesant H.S., 345 Chambers St., NY, NY 10282 Pier #25 Lab ID# Client Sample Location Volume Gnd Filter Analytical Asbestos Asbestos Structures Detected Structure Density Structure Sample (liters) Openings Area Sensitivity Type(s) (microns) (struc/mm^) Concentration ID# Examined (mm^) (struct/cc air) Total (struc/cc) O.5-5.O >5.0 Total Total T0112!5b-01 Outside North Entrance of School - W Side 1428 6 385 0.0045 ND 0 0 0 <16.67 < 0.0045

T011215b-02 2 Outside North Entrance of School - E Side 1428 6 385 0.0045 ND 0 0 0 <16.67 < 0,0045

Area Analyzed: 0.0600 mm^ Date Received: 12/15/01 Grid Opening Area: 0.010 mm- Date Analyzed: 12/15/01 o Date of Report: 12/16/01 Date Collected: 12/14/01(16:00-24:00) H Analyst: p Dab Manager: David Chen David Chen Analysis perfonnedaccordingto AHERA Method (EPA 40 CFR Part 763 - Appendix A).Samples will be stored for ninety (90) days and then returned to the client upon request. S O Sample volume is below recommended limit of the method AIHA #: 100269 niST-NVLAP #: 102047 NYS-DOH ELAP#: 11273 O

4^ CO

NYC-WTC_000359163

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000359163Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →