SUMilARY REPORT STUYVESANT HIGH SCHOOL AIR SAMPLING RESULTS January, 2002

DATE TIME LOCATION RESULTS IN EPA STRUCTURES/MM^ GUIDELINE i/2/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00 70 s/mm" Pier 25 - North entrance of HS/West nsd<2o7oo 1/3/02 7 AM - 5 PM Pier 25 - North entrance of HS/East "NSD < 20.00 70 s/mm" Pier 25 - North entrance of HS/West NSD < 20.00 1/4/02 7 AM - 5 PM Pier 25 - North entrance of IIS/East NSD < 20.00 70 s/mm“ Pier 25 - North entrance of HS/West NSD < 20.00 1/5/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00 70 s/mm*' Pier 25 - North entrance of HS/West NSD < 20.00 1/6/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00 70 s7mnr Pier 25 - North entrance of HS/West NSD < 20.00 1/7/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00 70 s/mm" Piert25 - North entrance of HS/West NSD < 20,00___ 1/8/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 2O.6o' 70 s/mm" Pier 25 - North entrance of HS/West NSD < 20.00 1/9/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00____ 70 s/mm^ Pier 25 - North entrance of HS/West NSD < 20^0 1/10/02 7 AM - 5 PM Pier 25 - North entrance of HS/East NSD < 20.00 70 s/mm" Pier 25 - North entrance of HS/West NSD < 20.00

NSD = no structures detected

Regulatory standards; All samples were analyzed using transmission electron microscopy (TEM), which provides results that are specific for the presence of asbestos fibers. Using this method, the EPA guideline for acceptable concentrations is 70 structures per o square millimeter (s/mm"). H H

L Copy to: Calvin Drayton, NYC OEM, fax# 212-245-0666 NJ

SO

o co Page 16 of 16 Updated: January 13, 2002 3:36 PM (JI

CO (^

NYC-WTC_000358049

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000358049Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000266588

Summary report of air sampling results at Stuyvesant High School for January 2002.

Similar indexed content

NYC-WTC_000341197

Summary report of air sampling results at Stuyvesant High School, Jan 2002.

Similar indexed content

Compare copies and versions →