Weekly summary, 11/25/01 metals and silica

Machine-extracted title · confidence 36%

Table of metals, silica, toluene exposures with TLV/PEL context.

NYC-WTC_000357895
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

Llbsrty Mutual / ATC Measurement Data

Weekly Summary

#of #of Highest Highest OSHA ACGIH Highest Result Job With Highest #ofNQs % NQ Goraments Week of: Agent Class Samples Analyses Analyte Resuit PEL TLV % of PEL Exposure

11/25/01 Total Dust/Metals 17 340 Cadmium 2.6ug/rn3 5ug/m3 lOug/ma 56% Of PEL Torch cutter 198 58% 11/25/01 Reap. Dust/Sillca 13 39 Quartz aoiBmg/mS 0.1 mg/m3’ O.osmg/mS 38% of TLV Spotter 27 69% 11/25/01 Aromatics 7 28 Toluene 0.0038 ppm 200 ppm 50 ppm 0.0076% Of TLV Torch Cutter 26 93% 11/25/01 Aioehydss 3 21 Formaidehycle 0.010 ppm 0.76 ppm o,3ppm(Csiisnc) 1.3% or PEL Backhoe operator 15 71% 11/26/01 PAHS 6 96 Total PAHS 6.8 ufl/rn3 20Oug/m3 200 ug/m3’’ 3.4% Of PEL Grapplar Operator 75 78% 11/25/01 Asbestos 24 24 Fibers 0.033f/oe 0.1 f/« 0.1f/ec 33% Of PEL Spotter 4 17% 11/25/01 Adds 6 80 Hi/drBfluorlcAcid 0.01 ppm 3 ppm 3 ppm (Calling) 0.33%ofTLV Gr^plsr Operator 50 98% 11/26/01 Ozone 2 2 N/A All'Too Low to Quantify" 11/26/01 Carbon Monoxide (TWA) 26 26 Carbon Monoxide 33 ppm SO ppm 25 ppm 132% of TLV (abbreviated Flagman IS 58% 1 peak over NIOSH Ceiling of 200 sample-2 hrs, 8 min) ppm (Greppter Operator) Totals; 104 636

Notas;

Tbs PEL. for quartz is detamlned by ths formuia PEL »10 mg/mS / {% qustz *2). For dusta with high quartz contant thia works out to bs a quartz concentration of approxtmatety 0.1 mg/mS.

"OEL"«"occupatione’ expoaura limit". A generic tarn encompassing PELs, TLVs end other wokplace exposure limits.

■'NQ'' = "not quantlfisbls” Substance was was not present In sufficient quantity in the sample to report a firm value for the concentration. All quantfflcstlon levels for the sampling methods used are well below occupational exposure limits.

S Q

I

LO to

NYC-WTC_000357895

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000357895Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →