LIBEWl
MUTUAL W T*.’' ■
Industrial Hygiene Air Sample Results
Summary for Week of 01/11/02-01/18/02
Attached is a summary of the results ofthe samples collected by ATG associates at the World Trade
Center site for the specified week.
The vast majority of the samples collected by ATC are “personal samples”, meaning that the worker wore
the sampling device. The vast majority ofresults have shown exposure levels to be below occupational
exposure limits. The exceptions were:
• A Diesel exhaust fume concentration of 102% ofthe OEL on torch cutter in the WTC 1
depression
• A quartz concentration of 466 % of the OEL on a jackhammer operator west of wash
station
In addition, the following results are above 50% of the OEL (but below 100% ofthe OEL) and represent
operations that should be sampled again to verify airborne concentrations.
• An ozone concentration of 81 % of the OEL on a drill operator in the depression
• A Diesel exhaust fume concentration of 86% of the OEL on torch cutter in the WTC 1
depression
• A Diesel exhaust fume concentration of 91% of the OEL on torch cutter in the WTC 1
depression
• A Diesel exhaust fume concentration of 56% ofthe OEL on torch cutter in the WTC 1
depression
• A Diesel exhaust fume concentration of 98% of the OEL on truck operator moving
material to surfoce
• A quartz concentration of 62 % of the OEL on a slurry wall drill operator
• A quartz concentration of 72 % of the OEL on a jackhammer operator in the cable pit
• A quartz concentration of 96 % of the OEL on a drill operator
• An asbestos concentration of 56 % of the OEL on a grappler operator
Some of the columns in the attached summary may require explanation:
Analyte Class - This column includes general category of the agents (substances) which were sampled.
# of Samples - This indicates how many individual samples were collected for the agent class listed.
# of Analytes - This is thenumber of individual analysis performed. Ifonly one analyze is determined on
each sample, then the number of analytes will equal the number of samples. However, most samples are
analyzed for more than one agent as follows:
Metals: Aluminum, antimony, arsenic, barium, beryllium, cadmium, calcium, chromium, cobalt,
copper, iron, lead, magnesium, manganese, nickel, selenium, silver, thallium, tin, titanium,
vanadium, and zinc. Metal samples are sometimes also analyzed for total particulate.
Ei
i 1---- z.aT -1 u lu ----- ----
CITY_21MC100_011914305
NYC-WTC_000357814
OCR can misread numbers and units. Confirm readings against the page image before using them.