NYC 9/11 Public Portal Document
liberty
Mutual™
Industrial Hygiene Air Sample Results
Summary for Week of 04-15-02 to 04-19-02
Attached is a summary of the laboratory results completed during the week of April 1.5, 2002 to
April 19, 2002. The air samples were collected by ATC associates at the World Trade Center site.
The majority of the samples collected by ATC are “personal samples”, meaning that the worker wore
the samphng device. In addition, the majority of results have shown exposure levels to be below
shift adjusted occupational exposure hmits. Those results wliich were higher than the shift adjusted
occupational exposure limits were;
• Three Quartz concentrations as follows;
• 791 % of the shift adjusted OEL on a spotter at WTC 1 Depression.
• 625 % of the shift adjusted OEL on a laborer WTC 5, B2.
• 279 Yo of the shift adjusted OEL on operator middle of south slurry wall
Three Diesel exhaust fume concentration as follows;
• 225 % of the shift adjusted OEL on a laborer in WTC 5.
» 212 % of the shift adjusted OEL on a bobcat operator in WTC 5, B2.
• 145 % of the shift adjusted OEL on a laborer cleaning beams WTC 5, Bl.
In addition, the following results were at or above SOYo of the shift adjusted OEL (but below 100%
of the sliift adjusted OEL). The operations associated with these results should receive attention to
ensure that these results are an accurate reflection of actual exposures and that feasible steps are
taken in an attempt to ensure that exposures do not elevate over time;
• Five Quartz concentrations of 96 %, 92 %, 88 %, 79 % and 70 % of the shift
adjusted OEL on a laborer in WTC 6, B2- core drilling, area- mid bridge, WTC 5 torch
cutting, WTC 5 Bl - scaffold area, WTC 5 , B2 breaking concrete.
® Four Diesel Exhaust Particulate concentration at 85 %, 71 %, 71 ‘/o, 51 % and 50 %
of the shift adjusted OEL on a torch cutter on .scaffold at truck exit, laborer WTC 5
sublevel, Torch cutter in depression WTC 5, excavator operator WTC 4.
Some of the columns in the attached summary may require explanation;
Analyte Class - This column includes general category of the agents (substances) which were
sampled.
# of Samples - This indicates how many individual samples were collected for the agent class listed.
# of Analysis - This is the number of individual analyses performed. If only one analysis is
performed on each sample, then the number of analytes will equal the number of samples.
However, most samples ate analyzed for more than one agent as follows;
1
............................ .....
CITY_21MC100_011914272
NYC-WTC_000357726