5 * (,
OSHA SAMPLING RESULTS SUMMARY AS OF 11/27
Asbestos: A total of 695 air monitoring samples for asbestos have been taken. From 9/13 -
9/21,177 samples were taken in the financial district. They were taken on OSHA
personnel as they walked within certain predetermined zones. Results revealed
asbestos concentrations ranging from ND (none detected) to .037 f/cc., well below
OSHA’s permissible exposure limit (PEL) of .1 f/ec.
After 9/21, sampling focused on the rubble pile and those workers working on or
immediately next to it. 82 of the samples analyzed exceeded OSHA’s limit via
PCM analysis. However, upon further analysis using discriminating counting
methods and/or TEM analysis, the number of asbestos fibers found dropped
dramatically to below detectable levels or well below .1 f/cc.
Carbon Monoxide: A total of 77 personal samples of workers on the rubble pile showed results ranging
from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible
exposure limit.
Noise: OSHAhas been conducting noise monitoring in the rubble pile. 18 personal samples
have been conducted on employees performing (or working near) various operations
such as jack hammering, drilling and equipment operations. Employee’s exposure
to the noise range from 73.7 dBA to 94.5 dBA. OSHA’s permissible noise
exposure for construction is 90 dBA. One personal sample and one area sample
during core drilling operations exceeded the OSHA noise PEL of 90 dBA. OSHA
continues to recommend the use of appropriate hearing protection for workers
performing tasks where high noise levels are likely to be encountered.
Respirable
Silica: The overwhelming majority of the 307 silica samples show no detectable levels of
airborne silica. However, the highest sample result was approximately nine times
the OSHA limit on pre-drillers working on the slurry or “bathtub” wall. The only
other exposures that appear to be over the PEL level were approximately twice the
OSHA limit. These exposures occurred during: 1) rubble removal and loading
operations near the Winter Garden; 2) during thebreaking up of concrete in the pit;
and 3) while drilling and coring the concrete slurry wall. All of the work areas
where apparent overexposures to silica occurred were in the rubble pile; an area
where OSHA continues to encourage the use of respiratory protection.
Volatile Organic
Compounds: OSHA has taken 452 samples for (VOCs) such as acetaldehyde, acrolein,
acrylonitrile, benzene, 2-butanone, carbofurans, chlorodiphenyl (PCB), ethyl
benzene, formaldehyde, Freon R-22 (chi orodiflouromethane), hexone, isocyanates
(e.g. MDI, TDI), perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene,
trichloroethylene, vinyl chloride, and xylene. Screening samples initially showed
elevated levels of some organic chemicals resulting from the fires burning in the
rubble pile. Subsequent personal and area samples show worker exposure levels to
be below OSHA limits. However, one personal sample result for benzene was found
to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found
Page 1 of 2
CITY_21MC100_009249473
NYC-WTC_000357565
OCR can misread numbers and units. Confirm readings against the page image before using them.