NYC 9/11 Public Portal Document
on a backhoe operator moving debris. See information below for polynuclear
aromatics, Freon R-22, phosgene and dioxin.
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees manning truck
wash stations revealed trace levels of nitric oxide and nitrogen dioxide. SO,
personal and area results were found to be below OSHA limits.
Metals: OSHA has taken 491 air samples to monitor worker exposures to dusts, fumes,
oxides, and other compounds of metals such as antimony, beryllium, chromium,
cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc,
cadmium, magnesium, arsenic, and mercury. Results from these samples are
generally well below the applicable OSHA limits. However, torch cutting and
burning structural steel at the rubble pile have resulted in instances of
overexposures as follows: copper (7); iron oxide (8); lead (7); and cadmium (2).
Accordingly, OSHA is recommending that workers engaged in these operations
wear appropriate respiratory protection.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent
radiation with particular attention to alpha radiation. Preliminary results show no
elevated levels.
Dioxins: OSHA has taken samples for dioxin and these samples were analyzed by EPA. One
initial sample, representing exposure directly on the pile, showed elevated levels of
dioxins when compared to ambient background levels. This value was comparable
to the levels found by EPA sampling. The dioxins at this location are being emitted
from the on-going rubble fire. Additional sampling was conducted around the
perimeter ofthe pile and revealed levels that were considerably lower than those on
the rubble pile. Dioxins are considered collectively as suspect human carcinogens.
OSHA has taken additional samples which have all been forwarded for analysis.
OSHA does not have a worker standard for dioxins. OSHA is coordinating with
EPA, and the Salt Lake City Analytical Laboratory to fully assess the risk posed by
the elevated levels of dioxins.
Polynuclear
Aromatic
Hydrocarbons: OSHA has taken 96 samples. Sample results to date have identified several elevated
samples, four of which reached or exceeded OSHA’s coal tarpitch volatile PEL of
0.2mg/m^’ These personal samples were taken on the pile on iron workers and
grappler operators. OSHA continues to strongly recommend the use of respiratory
protection when working on the rubble pile.
FreonR-22,
Hydrogen Fluoride
& Phosgene: OSHA has taken 47 samples for Freon R-22 (chlorodiflouromethane). Sample
results received to date reveal non-detectable airborne levels. In response to
information about exposure to the decomposition by-products of Freon R-22 used
in the air conditioning systems of WTC towers, sampling for hydrofluoric acid (HF)
had been conducted. Results for HF revealed non-detectable levels. Sample
results for phosgene to date show non-detectable levels. H
Page 2 of 2
CITY_21MC100_009249474
NYC-WTC_000357566
OCR can misread numbers and units. Confirm readings against the page image before using them.