JLC ENVIRONMENTAL CONSULTANTS, INC.
200 Park Avenue South, Suite 1001, New York, New York 10003
Phone: <212) 420-8119 Fax: (212) 420-6092
Project No.: 01-2102
Metcalf & Eddy Inc. ELAP Lab Code: 11029
Analyte: ASBESTOS
3 Werner Way, Suite 310 NIOSH and AIHA f .ab Code: 100273
Date Received: 9/28/01
Lebanon, NJ 08833 NVLAP Lab Code: 101953
Date Analyzed; 9/28/01
SUMMARY OF ANALYTICAL RESULTS - PLM Batch #: 0109B384
Site: 3 World Financial Center - Floors 3-26
SAMPLE #
ASBESTOS TOTAL % OF
DATE DESCRIPTION /LOCA TION COLOR DETECTED? ASBESTOS CONSTITUENTS
COLLECTED
LABH
CLIENT'S SAMPLE #
24005 24th Floor/ Area of Damage at South East TAN/ NO 0% FBGL 5%
9/27/01 Corner of Building/ Sample of Debris BROWN NFIB 95%
10941
24-005
24006 24th Floor/ Area of Damage at South East CREAM YES 40% CHRY 40%
9/27/01 Corner of Building/ Sample of Debris CELL 2%
10942 NFIB 58%
24-006
24007 24th Floor/ Area of Damage at South East CREAM YES 30.8% CHRY 30.8%
9/27/01 Corner of Building/ Sample of Debris GELL 2.2%
10943 FBGL 12%
NFIB 55%
24-007
24008 24th Floor/ Area of Damage at South East GRAY TRACE <1% CHRY <1%
9/27/01 Corner of Building/ Sample of Debris CELL 25%
10944 FBGL 60%
NFIB 15%
24-008
‘INSUFFICIENT MATERIAL SUBMITTED *n-EM RECOMMENDED ***NOT ANALYZED POSITIVE STOP
ASBESTOS CONSTITUENTS NON-ASBESTOS CONSTITUENTS
Sample Analysis by:
Polarized Light Microscopy-Dispersion Staining (PLM-DS) CHRY = Chrysotile Asbestos PAPF = Paper Fiber
AMOS = Amosite Asbestos MINV/ = Mineral Wool
CROC = Crocidolite Asbestos FBGL = Fiberglass
Method of Sample Preparation and Analysis: ACTN = Actinolite Asbestos SYNF = Synthetic Fibers
Afi samples were prepared and analyzed In accordance with the EPA TREM = Tremolite Asbestos CELL = Cellulose
"Method for the Determination of Asbestos in Bulk Building Materials" ANTH = Anthophylite Asbestos NFIB = Non-Fibrous
USEPA/ 600/ R-93/116. July 1993. ORGM = Organic Material
WOLL = Wollastonite
Instrumentation: HSHR = Horse Hair
OTHR = Other
Olympus PLM, Model BH-2/VM Stereomicroscope, Model
VMZ fx-4x. Gulam Machhiwala
Laboratory Director
Analytical results reflect the make up of the materials only in the areas sampled. This “Summary of Analytical Results" shall not be reproduced except in full, without the writte
approval of JLC Laboratory, and it must not be used by client to claim product endorsement by NVLAP or any agency of the U.S. Government. This method is not applicable to
samples containing large amounts of fine fibers below the resolution of the light microscope. The value of this method is limited to the quantitative identification of asbestos
and the semi-quantitafive determination of asbestos content of bulk samples, expressed as a percentage of the protected area. Quantitation of asbestos content was
determined with a visual volume estimate, araiibrated visual area estimate, and/or point counting procedure. CAUTION; Other libers with optical properties similar to asbesto
may give positive interferences and will be considered asbestos under this methodology. Also, PLM Is not consistently reliable in detecting asbestos in floor coverings and
similar non-friable organically-bound materials. Quantitative transmission electron microscopy is currently the only method that can be used to determine if this material can b
considered or treated as non-asbestos containing.