NYC 9/11 Public Portal Document
New York State Department of Labor
Division of Safety and Health
Sampling Sunnnary as of 12/26/200!
Personal exposure sampling has been performed on numerous employees working on and
around the WTC site. This has included firefighters, police officers, state troopers, corrections
officers, police defectives, and sanitation workers. The New York Slate Department of Labor has
to date collected over 190 personal exposure samples on public employees working at the site
with over 950 analyses perfonued. The sampling sununary below is for activity up to
12/12/2001.
xA.sbestos Over 30 personal samples have been collected so far with results ranging
from not detectable to 0.116 fibers per cc by PCM analysis. The use of
TEM on the samples which initially were above the PEL of 0.1 fibers per
cc resulted in a reduction to at least 0.016 fibers per cc. Most results by
PCM analysis have been well below the PEL of 0.1 fibers /cc.
Carbon Monoxide Results have ranged from 0 to 11 ppm as a time weighted average, still
below the PESH PEL of 35 ppm.
Silica Personal sampling results have shown most exposures to be below the
detection limit for respirable silica with all exposures well below the
PESH PEL of 0.1 mg/m3
Metals Personal samples collected show all exposures to be below the PESH
PELs. Metals analyzed included lead, copper, manganese, molybdenum,
magnesium, cadmium, nickel, iron, aluminum, zinc, and cobalt.
Volatile organics All personal sampling results have been well below PESH limits for
acetone, benzene, ethyl benzene, butyl alcohol, isopropyl alcohol, naphtha,
' styrene, toluene, and xylene.
Acid gases Exposures to acid gases such as hydrogen bromide, hydrogen chloride,
hydrogen cyanide, and hydrogen fluoride were all below the detection
limit. For sulfuric acid, the highest exposure was at a level of 0.48 mg/ra3,
less than half of the limit of 1 mg/m3
PCBs The two personal exposure samples for PCBs on workers monitoring the
debris pile had results which were less than the detection limits.
CITY_21MC100_008111850
NYC-WTC_000355994
OCR can misread numbers and units. Confirm readings against the page image before using them.