OSHA SAMPLING RESULTS SUMMARY AS OF 1/2/02
Asbestos: A total of 931 air monitoring samples for asbestos have been taken. From 9/13 -9/21, 177
samples were taken in the financial district. They were taken on OSHA personnel as they
walked within certain predetermined zones. Results revealed asbestos concentrations
ranging from ND (none detected) to .037 f/cc., well below OSHA’s permissible exposure
limit (PEL) of .1 free. After 9/21, sampling focused on the rubble pile and those workers
working on or immediately next to it. 82 of the samples analyzed exceeded OSHA’s limit
via PCM analysis. However, upon further analysis using discriminating counting methods
and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below
detectable levels or well below .1 free.
Carbon Monoxide; A total of 98 personal samples of workers on the rubble pile showed results ranging from 1
ppm to 34 ppm which are well below the OSHA permissible exposure limit of 50 PPM.
Noise: OSHA is monitoring the noise exposures of employees who perform (or work near) noisy
operations such as jack hammering and drilling. To date the 79 samples collected indicate
that employee noise exposures range from 73.7 dBA to 94.5 dBA. One personal sample
and one area sample taken during core drilling operations have exceeded the applicable
permissible exposure limit of 90 dBA. Accordingly, OSHA continues to recommend the
use of appropriate hearing protection in noisy operations.
Respirable
SUica: The overwhelming majority ofthe 466 silica samples show no detectable levels of airborne
silica. However, fifteen exposures exceeded the PEL. The highest sample result was
approximately nine times the OSHA limit (pre-drillers working on the slurry or “bathtub”
wall). The other twelve elevated exposures were approximately one to seven times the
OSHA limit. These exposures occurred during; 1) rubble removal and loading operations
near the Winter Garden; 2) during the breaking up of concrete in the pit; 3) while core
drilling the concrete slurry wall, and 4) while chipping concrete with power tools during
demolition activities at 7 WTC’s parking garage. Most of the work areas where apparent
overexposures to silica occurred were in the rubble pile; an area where OSHA continues to
encourage the use of respiratory protection.
Organic
Compounds: OSHA has taken 614 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile,
benzene, 2-butanone, carbofurans, PCBs, ethyl benzene, formaldehyde, Freon R-22
(chlorodiflouromethane), hexone, isocyanates (e.g. MDI, TDI), perchloroethylene,
phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, glutaraldehyde,
and xylene. Screening samples initially showed elevated levels of some organic chemicals
resulting from the fires burning in the rubble pile. Subsequent personal and area samples
show worker exposure levels to be below OSHA limits. However, one personal sample
result for a benzene sample taken was found to be at the 8-hr. OSHA Allowable Limit
concentration of 1 ppm. This was found on a backhoe operator moving debris on 10/7/01.
See information below for polynuclear aromatics, Freon R-22, phosgene and dioxin.
Inorganic Acids OSHA has taken approximately 48 samples for inorganic acids such as hydrochloric,
phosphoric, and sulfuric acids. One sample for sulfuric acid was found to exceed OSHA’s
permissible exposure limit (PEL) of 1 mg/m\ Additional sampling results are pending.