NYC 9/11 Public Portal Document
Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees at the truck wash
stations revealed trace levels of nitric oxide and nitrogen dioxide. This was repeated t i
sample, now that the wash station is been enclosed. SO, personal and area results were
found to be below OSHA limits.
Metals: OSHA has taken approximately 700 air samples to monitor worker exposures to dusts
fumes, oxides, and other compounds of metals such as antimony, beryllium, chromium.
cobalt, copper, iron, lead, manganese, molybdenum, nickel, vanadium, zinc, cadmium,
magnesium, and arsenic. Results from these samples are generally well below the
applicable OSHA limits. However, torch cutting and burning structural steel at the rubble
pile have resulted in instances of overexposures as follows; copper (12); iron oxide (23);
lead (12); and cadmium (2). Accordingly, OSHA is recommending that workers engaged
in these operations wear appropriate respiratory protection.
Mercury OSHA has taken 81 air samples for inorganic mercury. Results for 74 of those air samples
have been received and no mercury was detected. Also, 37 bulk samples previously
collected from rubble were re-analyzed for mercury. None was detected.
Ionizing Radiation: A survey of the rubble pile was conducted on 10/22-10/23 to check for latent radiation with
particular attention to alpha radiation. Preliminary results show no elevated levels.
Dioxins: OSHA has taken 15 dioxin samples in the plume over hot spots in (and around the
perimeter of) the rubble pile. Dioxin levels detected around the perimeter are lower than
those found directly over the pile. To date, only one sample taken on the rubble pile
showed dioxin levels which exceeded background levels. Dioxins are considered
collectively as suspect human carcinogens. OSHA does not have a PEL for dioxins.
Polynuclear Aromatic
Hydrocarbons OSHA has taken 132 samples. The majority of the samples have not shown the presence of
benzo(a)pyrene and/or one or more of five additional fused polycyclic hydrocarbons;
anthracene, acridine, pyrene, chrysene and phenanthrene. Sample results to date have
identified eight samples which reached or exceeded OSHA’s coal tar pitch volatile PEL of
0.2mg/m^. These personal samples were taken on the pile on iron workers and grappler
operators. OSHA continues to strongly recommend the use of respiratory protection when
working on the rubble pile.
Freon R-22,
Hydrogen Fluoride
& Phosgene; OSHA has taken 137 samples for Freon R-22 (chlorodiflouromethane). The majority of
sample results received to date show no detectable airborne levels. During operations
involving Freon removal from the auxiliary chiller, direct reading instruments used by the
entrants revealed readings ranging from 100 ppm to 500 ppm. SCBA ‘s were and are
being worn by workers, and masks are to be worn only when direct reading instruments
reveal 850 ppm Freon and/or less than 20.4% Oxygen. OSHA does not have an exposure
limit for Freon R-22. (The NIOSH REL for Freon is lOOOppm..) Sampling for
decomposition products of Freon R-22 for hydrofluoric acid (HF) and phosgene to date
showed no detectable levels.