Oxides of Nitrogen/
Sulfur: Sampling on grappler operators on the rubble pile, and on employees
manning truck wash stations revealed trace levels of nitric oxide and
nitrogen dioxide. SO, results are pending.
Metals: As of 10/23/01 OSHA has taken 293 air samples to monitor worker exposures
to dusts, fumes, oxides, and other compounds of metals such as antimony.
beryllium, chromium, cobalt, copper, iron, lead, manganese, molybdenum.
nickel, vanadium, zinc, cadmium, magnesium, arsenic, and mercury . Results
from these samples are generally well below the applicable OSHA limits.
However, torch cutting and burning structural steel at the rubble pile have
resulted in instances of overexposures as follows: copper (7 ); iron oxide (7):
lead (3); and cadmium (3). .Accordingly, OSHA is recommending that
workers engaged in these operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for latent
radiation with particular attention to alpha radiation. Preliminary results show
no elevated levels.
Dioxins: The single sample taken by OSHA and analyzed by the EPA, representing
exposure on the pile, showed elevated levels of dioxins, fhese levels were
substantially higher than background levels but comparable to levels found by
the EPA on the rubble pile. The dioxins found here are emitted from the on
going rubble fire. OSHA does not have a worker standard for dioxins.
Dioxins are considered collectively as suspect human carcinogens. Some of
the individual compounds are considered to be known human carcinogens.
OSHA has taken additional samples which have all been forwarded for
analysis. OSHA is coordinating with EPA, and Salt Lake City Analytical
Laboratory to more fully characterize exposure and risk around the rubble pile.
Polynucleated
Aromatic
Hydrocarbons: OSHA identified several elevated samples, three of which reached or exceeded
OSHA’s coal tar pitch volatiles PEL of .2mg/m’ These personal samples
were taken on the pile on iron workers and grappler operators. OSHA
continues to strongly recommend the use of respiratory protection when
working on the rubble pile.
Freon R-22: OSHA has conducted sampling for Freon 22 and the sample results are
pending. In response to information about exposure to the decomposition by
products of Freon 22 used in the air conditioning systems of WTC towers,
sampling for hydrofluoric acid (HF) had been conducted. Results of the HF
revealed non-detectable levels. Additionally, sampling for phosgene has also
been conducted and the sample results are pending.