OSHA SAMPLING RESULTS SUMMARY AS OF 11/5

Asbestos: A total of 635 air monitoring samples for asbestos have been taken. From 9/13 -9/21, 177 samples were taken in the financial district. They were taken on OSHA personnel as they walked within certain predetermined zones. Results revealed asbestos concentrations ranging from ND to .037 f/cc., well below OSHA’s permissible exposure limit (PEL) of .1 f/cc.

After 9/21, sampling focused on the rubble pile and those workers working on or immediately next to it. 63 of 458 samples exceeded OSHA’s limit via PCM analysis. However, upon further analysis using discriminating counting methods and/or TEM analysis, the number of asbestos fibers found dropped dramatically to below detectable levels or well below .1 f/cc.

Carbon Monoxide: A total of 47 personal samples of workers on the rubble pile showed results ranging from 1 ppm to 34 ppm which are well below the OSHA 50 ppm permissible exposure limit.

Noise: OSHA has been conducting noise monitoring in the rubble pile. Twelve personal samples have been conducted on employees performing (or working near) various operations such as jack hammering. Employee’s exposure to the noise range from 80.6 dBA to 89 dBA. OSHA’s permissible noise exposure for construction is 90 dBA

Respirable Silica: The overwhelming majority of the 226 silica samples show no detectable levels of airborne silica. The highest sample result was approximately twice the OSHA limit, whereas the next highest level was less than half of this limit. Both of these levels were found on personnel working in the rubble pile; an area w'here OSHA continues to encourage the use of respiratory protection.

Volatile Organic Compounds; OSHA has taken 357 samples for (VOCs) such as acetaldehyde, acrolein, acrylonitrile, benzene, 2-butanone„ chlorodiphenyl (PCB), isocyanates (e.g.MDI, TDI), ethyl benzene, freon, formaldehyde, hexone, perchloroethylene, phosgene, styrene, toluene, 1-3 butadiene, trichloroethylene, vinyl chloride, carbofurans, and xylene. Screening samples initially showed elevated levels of some organic chemicals resulting from the fires burning in the rubble pile. Subsequent personal and area samples show worker exposure levels to be below OSHA limits. However, one personal sample result for benzene was found to be at the 8-hr. OSHA Allowable Limit concentration of 1 ppm. This was found on a backhoe operator moving debris. See information below for polynucleated aromatics and dioxin.

Oxides of Nitrogen/

Page I of 2

CONFIDENTIAL, CITY_2IMCI00_003477352 SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008

NYC-WTC_000407321

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000407321Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →