NYC 9/11 Public Portal Document
nitrogen dioxide. SO, results are pending.
Metals: As of 10/23/01 OSHA has taken 293 air samples to monitor worker
exposures to dusts, fumes, oxides, and other compounds of metals such as
antimony, beryllium, chromium, cobalt, copper, iron, lead, manganese,
molybdenum, nickel, vanadium, zinc, cadmium, magnesium, arsenic, and
mercury. Results from these samples are generally well below the
applicable OSHA limits. However, torch cutting and burning structural
steel at the rubble pile have resulted in instances of overexposures as
follows: copper (7); iron oxide (7); lead (3); and cadmium (3).
Accordingly, OSHA is recommending that workers engaged in these
operations wear appropriate respiratory protection.
Ionizing Radiation; A survey of the rubble pile was conducted on 10/22-10/23 to check for
latent radiation with particular attention to alpha radiation. Preliminary
results show no elevated levels.
Dioxins: The single sample taken by OSHA and analyzed by the EPA, representing
exposure on the pile, showed elevated levels of dioxins. These levels were
substantially higher than background levels but comparable to levels found
by the EPA on the rubble pile. The dioxins found here are emitted from the
on-going rubble fire. OSHA does not have a worker standard for dioxins.
Dioxins are considered collectively as suspect human carcinogens. Some of
the individual compounds are considered to be known human carcinogens,
OSHA has taken additional samples which have all been forwarded for
analysis. OSHA is coordinating with EPA, and Salt Lake City Analytical
Laboratory to more fully characterize exposure and risk around the rubble
pile.
Polynucleated
Aromatic
Hydrocarbons: OSHA identified several elevated samples, three of which reached or
exceeded OSHA’s coal tar pitch volatiles PEL of .2mg'm" These personal
samples were taken on the pile on iron workers and grappler operators.
OSHA continues to strongly recommend the use of respiratory protection
when working on the rubble pile.
Freon R-22: OSHA has conducted sampling for Freon 22 and the sample results are
pending. In response to information about exposure to the decomposition
by-products of Freon 22 used in the air conditioning systems of WTC
towers, sampling for hydrofluoric acid (HF) had been conducted. Results of
the HF revealed non-detectable levels. Additionally, sampling for phosgene
has also been conducted and the sample results are pending.
Page 2 of 2
CITY_21MC1OO_OO8918493
NYC-WTC_000354264
OCR can misread numbers and units. Confirm readings against the page image before using them.