POST-CLEANING TESTING OF VEHICLES AFFECTED BY
WTC COLLAPSE
1. Sampling Area: The sampling area will be as clean as feasible, wet-mopped and/or HEPA
vacuumed where feasible or required.
2. Vehicles will be cleaned using the DOH/AAA Protocol (attached), ensuring that the air circulating
system has been run for at least fifteen (15) minutes and the vehicle has been driven as per the
protocol.
3. a. Set the air circulating system on maximum setting (keep vent closed in recirculation mode).
b. Perform air monitoring inside the vehicle as per NIOSH Analytical Method 7400. The
passenger seat breathing zone (BZ) is the preferred location if a minimum of one sample is to be
taken. If more than one sample is taken, place one in front and one in back of vehicle in passenger
BZ.
4. Perform area air monitoring approximately 5’ from the front of the vehicle (area where air
circulating system intake is located).
5. All samples are to be analyzed by phase contrast microscopy as per NIOSH Analytical Method
7400. Results at or above the NYC standard for asbestos in community and residential buildings
of 0.01 f/cc shall be further analyzed by transmission electron microscopy (TEM) using NIOSH
Method 7402.
6. If the results of sampling exceed established criteria, clean vehicle again and repeat testing.
Criteria:
Phase contrast microscopy (PCM - NIOSH Method 7400) 0.01 f/cc (US and NYC standard for asbestos in
community and residential buildings).
Transmission electron microscopy (TEM - NIOSH Method 7402) 70 structures/min2 (AHERA school
standard)
If the outside area air sample equals or exceeds 0.01 f/cc, results of vehicle interior air sampling must be
adjusted or interpreted accordingly.