machine-extracted · confidence unavailable · Check page ↗DOHMH preliminary summary of IAQ measurements on 22nd floor at 225 Broadway.
NYC-WTC_000354112–000354114OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
since there was no damaged friable suspect asbestos containing material (.ACM) from which bulk samples could be obtained. Suspect ACM including ceiling tile and thermal system insulation (TSI) were either intact or enclosed and were in good condition. Wipe samples for possible surface contamination with respect to Pb were collected and analyzed using NIOSH analytical method #9100 which utilizes Atomic Absorption Spectrometry (AAS). These samples were obtained from windowsills.
Temp and RH were measured using a Thermohygrometer. Air velocity was measured using a Velocical Meter. Noise levels were measured using an Ametek Sound Level Meter (SLM).
Summary of Results
No levels/concentrations of COCl 2, CI2, NH3, SO2, NO2, H2S, HCHO, O3, Hg, and natural gas were detected throughout the space on the 22"*^ Floor. Trace concentrations of (< 0.1 ppm) of HC including paraffins were detected in the space. The levels were negligible.
CO levels within the range of 1.0 ppm to 10 ppm were detected within the space. These levels were well below the PEL 8hr-time weighted average (TWA) of 35 ppm, ceiling exposure limit (C) of 200 ppm, and immediately dangerous to life and health limit (IDLH) of 1200 ppm. Background (ambient) level of CO is approximately 0.19 ppm.
CO2 levels within the range of 450 ppm to 500 ppm were detected. These levels were well below the PEL of 5000 ppm. Background (ambient) level of CO2 is approximately 350 ppm. The CT level was 21% (normal). The level suggests that the air was neither deficient nor enriched.
Phase Contrast Microscopy results indicated that no asbestos fibers were detected (ND) throughout the space. The minimum limit of detection (LOD) for the laboratory was 0.003 fiber/cc. The PEL is 0.1 fibers/cc. The most recent ambient airborne asbestos result from samples that were taken by EPA in Lower Manhattan was 29.6 fibei7m7
Atomic Absorption Spectrometry results indicated that Pb levels within the range of 2.5 ug/wipe'to 18.7ug/wipeAvcrc detected on windowsills. However, these levels were well below the HUD guideline of 500 ug ff’.
Temp and RH along the north side of the space ranged from 64.2 °F to 74.9 °F and 40% and 55% respectively; along the south side ranged from 71.0 °F to 72.0 °F and 30% to 31% respectively; along the east side ranged from 70.5°F to 70.8°F and 30% to 31% respectively; along the west side ranged from 72.4°F to 74,6°F and 30% to 31 % respectively; and within the interior ranged from 72.1 °F to 73.0 °F and 30% to 31 % respectively. Temp and RH were maintained within recommended guidelines.
Air velocity measurements along the north side of the space ranged from 168 fpm to 800 fpm with an average air velocity of 328 fpm; along the south side ranged from 360 fpm to
CITY_2IMCl00_006717313
NYC-WTC_000354113
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000354092
DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279307
Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321987
DOH/DMH air monitoring on 23rd floor of 225 Broadway; detailed results and table in report.
12 shared non-person entities · 1 shared topics · similarity 0.966
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
9 shared non-person entities · 1 shared topics · similarity 0.955
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
7 shared non-person entities · 1 shared topics · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000106406
Memo detailing periodic environmental testing for asbestos, lead, silica, and dust at BMCC conducted in December 2001.
6 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000360376
Law Department Appendix K: indoor air and dust test results after WTC collapse.
8 shared non-person entities · 1 shared topics · similarity 0.944
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243565
EIA report for Law Department project at 100 Church Street by TRC.
9 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243668
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000243703
Environmental assessment prepared for NYC Law Department by TRC Engineers, April 8, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000232952
Chain of custody documentation for samples collected in September 2001 involving multiple New York locations and consulting firms.
5 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000366617
Environmental testing of building air quality and dust at 88 Pine Street after the World Trade Center event, Sept 2001.
4 shared non-person entities · 1 shared topics · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000354092
DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.
Similarity score 0.965 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321987
DOH/DMH air monitoring on 23rd floor of 225 Broadway; detailed results and table in report.
Similarity score 0.964 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000279307
Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.
Similarity score 0.963 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000321320
NIOSH summary of air sampling near World Trade Center debris; describes exposure assessment and protective measures.
Similarity score 0.956 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000320629
Talking points and Q&As about asbestos and dust sampling in lower Manhattan residences.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000307871
Draft report on ambient and indoor dust/air evaluations with TEM/PLM procedures for WTC cause.
Similarity score 0.955 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
DOHMH memo detailing October 2001 air monitoring results for indoor contaminants.
Similar indexed content
Preliminary indoor air monitoring results for 225 Broadway floor near WTC site.
Similar indexed content
NYC-WTC_000321987
DOH/DMH air monitoring on 23rd floor of 225 Broadway; detailed results and table in report.
Similar indexed content
NYC-WTC_000106330
Letter reporting asbestos testing results for air and dust at Borough of Manhattan Community College in February 2002.
Similar indexed content
NYC-WTC_000408671
Indoor air/dust tests after WTC collapse; metals, PCBs, dioxin analyses; one sample above standard.
Similar indexed content