NYC 9/11 Public Portal Document
104 East 25th St, 10th Fi
New York. New York 10010
www.atc-enviro.corn
212.353 8280
Fax 212.353.8306
ASSOCIATES INC.
September 20, 2002
Mr. Bernard P. Orlan
Director, Environmental Health & Safely
New York City Department of Education
28-11 Queens Plaza N< nth
Long Island City, NY 11101-4008
Re: Air Sampling lor Silica
Murray Berglraum High School (M520)
ATC Project No. 15-19125-0351
Dear Mr. Orlan:
ATC Associates Inc. (.ATC) is pleased to provide this report of the results of air monitoring for
silica-containing dust conducted on September 11, 2002, at the referenced school. The New York
City Department of Education (DOE) requested this monitoring prior to the resumption of
classes to verify that acceptable indoor air quality is being maintained.
Scope of Work
ATC collected a total of three (3) samples (and one blank) for respirable dust using pre-weighed
37mm PVC filters cornected to size-selective cyclones to remove the larger (non-respirable)
particles prior to deposition on the filters. All of the samples were collected indoors. The
samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association
accredited laboratory in Reading, PA. Analysis for silica was performed by x-ray diffraction
according to OSHA Method 142. A copy of the analytical report is attached.
Tenzin Namgyal, Industrial Hygienist, and Sonny Ramlal, Environmental Technician of ATC’s
New York City office, collected the samples consistent with generally accepted industrial
hygiene practices. The 'esults of the sampling represent conditions found on the date the samples
were collected.
Results
Samples were obtainei in the following locations: pt floor Main Lobby, floor hallway by
Room 339 and floor hallway by Room 518.
The results of all of the samples were below the detection limit for silica (<5.0 micrograms per
sample).
CITY_21MC100_003021554