NYC 9/11 Public Portal Document
104 East 25th St., 10th Fl
New York, New York 100'0
www.atc-enviro.com
212.353.8200
Fax 212.353.8306
ASSOCIATES INC.
September 23, 2002
Mr. Bernard P. Orlan
Director, Environmental Health and Safety
New York City Department of Education
28-11 Queens Plaza North
Long Island City, 11101
Re: Air Sampling for Hydrocarbons
P. S. 124M
ATC Project No. 15-19125-0350
Dear Mr. Orlan;
ATC Associates, Inc. (ATC) is pleased to provide this report of the results of air
sampling for volatile hydrocarbon compounds conducted on September 12, 2002, at the
referenced school. Tlie New York City Department of Education (DOE) requested this
sampling to verify that acceptable indoor air quality is being maintained.
Scope of Work
ATC collected three (3) samples for hydrocarbon compounds (HC) at specified locations.
Samples were collected for ten (10) hours using activated coconut shell charcoal tubes
connected to battery powered sampling pumps at a flow rate of 0.2 liters per minute.
Pumps were calibratt d before and after each sampling period. One blank tube was also
submitted. The samples were sent to PSC Analytical Services, Inc., an American
Industrial Hygiene y association-accredited laboratory in Reading, PA. Analysis was
performed by capillary gas chromatography/flame ionization detection (OSHA Method
7).
Tenzin Namgyal, Industrial Hygienist and Sonny Ramlal, Environmental Teclinician,
from ATC’s New York City office, conducted the sampling consistent with accepted
industrial hygiene prttctices. The results represent conditions on the day the samples were
collected.
Each sample was analyzed for a panel of sixteen (16) specific HC compounds. These
compounds were: pentane, acetone, methylene chloride, hexane, chloroform, methyl
chloroform, benzene, 1,2-dichloroethane, trichloroethylene, toluene, perchloroetyhylene
(tetrachloroethylene) chlorobenzene, ethylbenzene, styrene, cumene and xylenes. In
addition, two non-i dentified peaks, total other A-hydrocarbons and total other B-
hydrocarbons, were ’eported. The A-hydrocarbons are those, such as gasoline or light
alcohols, with boiling points less than that of benzene (176°F). The B-hydrocarbons are
those, such as mineral spirits or petroleum naphtha, with boiling points greater than that
of benzene. A copy of the analytical laboratory report is attached.