104 East 25th St New York, New York 10010 viww.atc-enviro.com 212.353.8280 Fax 212.353.8306 ASSOCIATES INC.

March 6, 2002

Mr. Bernard P. Orlan Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101

Re: Air Sampling for Silica P. S. 89M ATC Project No. 15-19125-0297

Dear Mr. Orlan:

ATC Associates, Inc. (ATC) is pleased to provide this letter report of air sampling for silica- containing dust conducted on February 14, 2002 at the referenced school. The New York City Board of Education (BOE) requested this sampling at the recommendation of Environ Corp., the consultant to the parents association.

Scope of Work

ATC collected ten (10) samples respirable dust using pre-weighed 37mm PVC filters connected to size-selective cyclones to remove the larger (non-respirable) particles prior to deposition on the filters. .411 samples were collected indoors. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association accredited laboratory in Reading, PA. One blank filter was also submitted. Silica analysis was performed by x-ray diffraction according to OSKA Method 142. A copy of the analytical report is attached.

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists of .AFC’s New York City office, collected the samples.

The assessment was performed consistent with generally accepted industrial hygiene assessment practices. As with all such assessments, there were inherent limitations created by constraints of time, operational and work practice variability, variations in air contaminant concentrations and sampling and analytical accuracy.

The results of the sampling represent conditions found on the dates of the survey and may not represent conditions found at other times. The infonnation presented m this report should be used by the BOE as a guide to assess the need for further improvements in current indoor air quality control activities.

RESULTS

Samples were obtained in the 1® floor hallway by cafeteria (North and South), cafeteria, gymnasium, auditorium, room 226 (north), room 204 (east), room 202 (south), 2”*^ floor hallway (south end), and 4"' floor hallway (south end).

CITY_21MC1OO_OO3O19168

NYC-WTC_000352034

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000352034Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →