NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

ATC fax cover to NYC BOE, Jan 2002

Machine-extracted title · confidence 28%

Fax from ATC Associates to NYC Board of Education referencing environmental health communication.

NYC-WTC_000351478–000351479
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

01/24/2002 09:41 FAX 212 353 8306 ATC gjOO2

)04 East 25th St/H New York. New York 1001Q vwvw.ato enviro.corriij'' 212.353.8280|* Fax 212.353.8309Ji ASSOCIATES INC. 1 Ip January 24, 2002 il Mr. Bernard P. Orian Director, Environmental Health and Safety New York City Board of Education 28-11 Queens Plaza North Long Island City, NY 11101 ! Re: Air Sampling for Metals High School of Economics and Finance (833M) ATC Project No. 15-19125-0291

Dear Mr. Orian;

ATC Associates, Inc. (ATC) is pleased to provide this report of air sampling for metals conducted on January 13, 2002, at the referenced school. The New York City Board of Education (BOE) requested this sampling to evaluate air quality in tire school building prior to re-occupancy. i 1

Scope of Work

Tenzin Namgyal and Wagdi Abdelshahid, Industrial Hygienists from ATC’s New York City office , collected the samples. Nine (9) samples for metals were collected from locations throughout the building. Samples were collected for ten (10) hours using 37 mra mixed cellulose ester filters coimected to battery-powered sampling pumps at a flow rate of 2 liters per minute. Pumps were calibrated before and after each sampling period. Seven (7) samples were collected inside the building and two (2) were collected outdoors. One blank sample was also submitted. The samples were sent to PSC Analytical Services, Inc., an American Industrial Hygiene Association-accredited laboratory in Reading, PA. Analysis was performed by NIOSH Methods 73 OOM. Each sample was analyzed for a panel of eleven (11) metals. The metals were aluminum (Al), cadmium (Cd), chromium (Cr), cobalt (Co), copper (Cu), iron (Fe), magnesium (Mg), manganese (Mn), molybdenum (Mo), nickel (Ni) and zinc (Zn). Copies of the analytical reports are attached.

The sampling locations were: Outdoors at the Main Entrance, the Main Lobby, 3”* floor Hallway ! ' A by Stair B, 5* floor by Stair A, 7* floor Hallway by the bridge, 8“* floor Kitchen, Room 906, 1 Room 1006 and the Roof by the air intake. ''1 ■! i

The established regulatory values for metals are intended for industrial workplace exposures and are not generally applicable to office/school settings. There are no standards for these metals in indoor air in non-industrial situations.

Air Sampling Results a. The metals that were found above the limits of detection were iron (Fe) and copper (Cu). The other nine metals were not detected. Table 1 lists the locations and the metal concentrations detected.

IF

NYC-VVTC_000351478 CITY_2IMCl0 0_0 0 091419 7

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000351478Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →