NYC 9/11 Public Portal Document
. JLJL-31-2002 12:49 UFT P.02
OLMSTED ENVIRONMENTAL SERVICES INC.
1992 ROUTE 9
GARRISON, NY 10524
(045) 424-4077
FAX (Q45] 424-3402
□esenv@3ol,com
Date; July 30,2002
To: Tom Casimir
From: Ed Olmsted, cm. CSP
Fax: 516 483-7631
Subject: Air Sampling for Volatile Organic Compounds
PS 65 Queens
On June 18,2002 a meeting was held at the New York City Department of Health
(NYCDOH), which included representatives of the United Federation of Teachers (UFT),
the New YoA Chy Board of Education (BOE), the New York State Department of
Health (NYSDOH), and ATC, an environmental sampling firm contracted to conduct
environmental tests in the school. The purpose of the meeting was to develop a sampling
strategy for determining whether volatile organic compounds (VOCs), present in the soil
and ground water under the PS 65, were migrating through the basement concrete slab
into the school.
Complaints of chemical odors end poor air quality have occurred in the school since it
was opened and occtqiied over five years ago- The New York State Department of
Environmental Conservation (NYSDEC) identified the presence of a number of
chemicals in the ground water under the school. Given the history of odors in the school
and the presence of chemicals under it, the NYCBOE has begun a study to evaluate
whether chemicals are migratmg from the soil and ground water into the school. The
study has included air sampling in the school using very sensitive methods to detect
VOCs. The air sampling in the school has been inconclusive and it has been impossible to
demonstrate with a reasonable degree of scientific certainty whether chemicals in the soil
and ground water are a source of VOCs in the building. The air sampling is inconclusive
because of confounding factors that cannot be controlled. These factors include the
following;
1. Levels of VOCs in air in the occupied spaces will vary due to changing
pressurization of the building as s result of nonnal operation of the ventilation
system and outdoor climate and wind conditions.
2. Levels of VOCs in air in the occupied spaces will vary due to contributions from
other building-related sources including materials and equipment
3. The degree of migration of VOCs through the slab varies with temperature
conditions.
CITY_21MC100_003016871
NYC-WTC_000350759