NYC-WTC_000351363
Memorandum noting IAQ measurements at PS 42M, DOE, Sep 2002.
11 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗Indoor air quality measurements at PS 42M; DOE requested assessment Sept 2002.
NYC-WTC_000350068–000350071OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Mr. Bernard P. Orlan September 6, 2002 Indoor Air Quality Assessment Page 4 P,S.42M ATCProiectNo. 15-19125-0342
* The measurements made during this assessment were instantaneous readings, the NPAAQS is a 24-hour average.
TVOC Concentration
TVOCs concentrations indoors ranged from 0 ppm to 0.8 ppm. The AIHA guideline for odor control is 1 ppm. The outdoor TVOC concentrations were 1.0 ppm and 1.6 ppm.
OBSERVATIONS
During this assessment, ATC noted the following: • There was construction going on outside the building; • The building has no central A/C; • People observed in only few rooms in the building.
findings
Based on the real-time measurements, the following findings are presented:
1. Concentrations of CO2, CO and TVOCs were within applicable standards and guidelines. 2. Nine (9) of the indoor temperature measurements were above the range of 73 to79 °F (at 50 percent relative humidity) recommended by ASHRAE Standard 55-1992 during the summer season. ASHRAE standards do not apply directly to a naturally-ventilated building. 3. Thirty-eight (38) of the indoor measurements for relative humidity were above the ASHRAE-recommended range of 30 to 60 percent for occupant comfort. 4. All of the indoor measurements for PM2.5 were above the USEPA recommended concentration of 40 pg/m^ for sensitive individuals such as asthmatic people and children and above the NPAAQS of 65 pg/m^ 24-hour average concentration of particulate matter 2.5 micrometers or less in aerodynamic diameter. At the time of ATC’s site visit there was construction going on outside the building, also the sensitivity of the Dust Trak® to high humidity may have influenced these results; 5. One of the outdoor TVOC,s measurement was above the AIHA guideline for odor control is 1 ppm.
It is our pleasure to provide these indoor air quality services to the New York City Department of Education. If you have any questions about this report, please call (212) 353-8280, extension 211 or 212.
Sincerely, J TC ASSOC/A TES INC Reviewed By:
James R. Cohn, CIH, CSP Senior Project Manager Regional Manager, Industrial Hygiene Division
Attachment
CITY_21MC100_004035923
NYC-WTC_000350071
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000351363
Memorandum noting IAQ measurements at PS 42M, DOE, Sep 2002.
11 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000207776
Report on indoor air quality measurements collected at a Department of Education school to verify acceptable air conditions.
11 shared non-person entities · 1 shared topics · similarity 1.000
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350145
ATC September 4-6, 2002 indoor air measurements at PS 42M for DOE.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309794
DOE-requested indoor air quality measurements at PS 42M, Sept 2002.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353230
DOE IAQ measurements collected at PS 42M on Sep 4, 2002.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239406
Report on indoor air quality measurements conducted at a New York City high school on September 9, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239336
ATC Associates report detailing indoor air quality measurements collected at Murray High School on September 9, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353212
Indoor air quality measurements at PS 42M on Sep 4, 2002 for DOEs program.
11 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239267
Report on indoor air quality measurements taken at Murray High School to verify acceptable air conditions.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000238984
Letter and report detailing indoor air quality measurements conducted at PS 124M on September 10, 2002 for the NYC Department of Education.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000239194
Report on indoor air quality measurements collected at Murray High School on September 9, 2002, to verify acceptable air conditions.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000202383
ATC Associates report on indoor air quality measurements collected at the school on September 9, 2002.
10 shared non-person entities · 1 shared topics · similarity 0.999
machine-extracted · confidence unavailable · Check page ↗No available related records indexed in this group.
Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000309812
DOE IAQ memo for PS 42M measurements conducted Sept 4, 2002.
Similarity score 1.000 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000350145
ATC September 4-6, 2002 indoor air measurements at PS 42M for DOE.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000351363
Memorandum noting IAQ measurements at PS 42M, DOE, Sep 2002.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000207776
Report on indoor air quality measurements collected at a Department of Education school to verify acceptable air conditions.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000309803
ATC indoor air quality memo regarding PS 42M measurements.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000353212
Indoor air quality measurements at PS 42M on Sep 4, 2002 for DOEs program.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000351363
Memorandum noting IAQ measurements at PS 42M, DOE, Sep 2002.
Similar indexed content
NYC-WTC_000207776
Report on indoor air quality measurements collected at a Department of Education school to verify acceptable air conditions.
Similar indexed content
NYC-WTC_000350145
ATC September 4-6, 2002 indoor air measurements at PS 42M for DOE.
Similar indexed content
NYC-WTC_000309794
DOE-requested indoor air quality measurements at PS 42M, Sept 2002.
Similar indexed content
NYC-WTC_000353230
DOE IAQ measurements collected at PS 42M on Sep 4, 2002.
Similar indexed content