NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

TEM asbestos analysis report, New Stuyvesant H.S.

Machine-extracted title · confidence 45%

Transmission electron microscopy analysis of air samples at New Stuyvesant High School exterior/interior areas.

NYC-WTC_000349648
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

<Satc ASSOCIATES INC. . -104 East 25th St., 10th Floor'

. , 'New York, New York 10010 , www.atc-enviro.com 212.353.8280' . Fax 212.353.8306

June J.,,. 2002 . N.Y-. C. Board of Education'. 2'8-11 ■ Queens .Plaza North' .1912 5 - 024’6 ■ ■ Long Island City,. NY 11101

Attri: Mr.'Bernard Orlan

Re: ' Report of; TEM .Analysis

Dear Mr. Orlan:

. Following are the results of transmission electron microscopy. (TEM) ; analysis of air ..samples from our 'Group No. 7985:

Project Name: New'-Stuyvesant H.S., 345 .Chambers Street, ' NY, NY- Location:.Exterior.and Interior of.Building and Roof Samples, received.: 06/06/02

These results will'- confirm and document the data transmitted today ‘ to Mr. Mark Terjesen, Project Manager, of .'our office. The analyses were performed in strict conformance with the methodology of the .-. AHERA Final Rule (40. CFR Part.763, Appendix A to Subpart E, .October 30,. 1987). , for clearance of ■ abatement sites .',2

The results of the sample analyses are .'as indicated'on'the attached'- document', i ■ ,

Copies of the Dench sheets are also- included as . stipulated by AHERA.■ Results reported as Struct/cc are a function of air volume- collected in. the. field and are, '.as such, not verifiable by this 2 . laboratory. ■ This report may be'reproduced only in its entirety and hot without prior permission of this, laboratory. If post-abatement inside samples pass, the response action may be considered to have been completed. The- analyses were supervised by. Dr. Michae-l A. Gorycki, Director of Electron - Microscopy.

We are . pleased to note that our TEM lab . has received. full .. accreditation from NVLAP, as is currently required for recognized " analysis of TEM air samples for AHERA projects, and also approval- under the NY State DOH ELAP program. These analyses were performed by ATC d/b/a ATC Associates Inc. Please contact me regarding any questions relating to these materials. ■ ‘ ■

Very- truly yours,

Michael. A. Gorycki, Ph.D. Director of Electron Microscopy

CITY_21MC100_003015021

NYC-WTC_000349648

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349648Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

No available related records indexed in this group.

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000349789

TEM analysis results for air samples at New Stuyvesant High School exterior/interior.

Similar indexed content

NYC-WTC_000349868

TEM analysis of air samples; exterior/interior and roof for Stuyvesant High School.

Similar indexed content

NYC-WTC_000349623

TEM analysis results for air samples at New Stuyvesant High School, received June 2002.

Similar indexed content

Compare copies and versions →