SciLabJob#; 202052099 Page 1 of 2 3 H Client Name; Applied Technology Services, Inc. -< I GJ Q

Summary of Bulk Asbestos Analysis Results § hj E024H

SdLab Client HG Sample Heat Acid Insoluble Cl Sample Sample# Area WeTgH Sensitive Soluble Nbn-AsEestos ** Asbestos % by ’*'* Asbestos % by Location (gram) Organic % Inorganic % Inorganic % PLM/DS TEM

01 26-051002-01 001 0.83 9.52 20.00 70.48 NAD NAD 121h Floor / Dust + Debris N/W Comw / 24' P x 20' S Top Of Act. 02 26-051002-06 004 0.028 42.86 53.57 3.57 NAD NAD 12th Floor / Dust / Top Of F/O Ins. CUNY R. Office Al Closet Door (LOW WEIGHT) 03 26-051002-08 007 0.011 63.64 9.09 27.27 NAD NAD 15lh Floor / AHU #2 / Filter Element Door Inside Temp. Wall (LOW WEIGHT) 04 26-051002-09 0.35 23.14 33.43 43.43 NAD NAD 16 ,5 Floor / Debris / N/W Corner 16.5 30' E Cooling Tower Area Along Wall 05 26-051002-10 0.119 24.37 51.26 24.37 NAD NAD 16.5 Floor/ Dust / Top Of Rectifier # 1 Elevator Meeh. Room 06 26-051002-1 1 0.062 17.74 1.61 79.05 NAD Chrysolile 1.6 15th Floor/ Hallway Outside Phone Room Above Insulation 07 26-051002-12 0.16 18.75 45.00 36.25 NAD NAD I5ih Floor / Hallway Outside Phone Room Above Steel Header 08 26-051002-14 0.096 36.46 34.38 28.17 NAD Chrysotile <1.0 15ih Floor/Dust On Top Of Cooling Tower 8' East Of Door ENO. Office W/Door To Roof 09 26-051002-15 0.507 14.40 28.99 56.61 NAD NAD B Floor / Debris / Exhaust Duct On Fire Protection CZZ On Futn. West Wall 10 26-051002-16 0.335 21.19 43.88 34.83 NAD Chrysolile Trace B Flcwr / Dust / East Side Of Unit AC-7 Air Intake o 11 26-051002-17 0.944 30.19 19.81 50.00 NAD NAD H K 4lh Floor / Dust -r Debris / Mastic / 75' West Of P403 Hallway I 12 26-051002-18 0.207 22.71 45.41 31.88 NAD NAD S Q 4th Floor / 25' W. Along Wall Of F-408 Hallway A Top Waler Fountains o o 13 26-051002-19 0.297 69.02 4.04 26.84 NAD Chrysotile Trace -I -D o I 4th Floor Dust / E. Wall 12' S Of Room F-405 Hall (S o rs o T3 Q cn ts. See Reporting notes on last page <73

NYC-WTC_000349350

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349350Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →