SECTION B. MONITORING REQUIREMENTS

1. Sampling

The industrial user shall monitor the specified discharge points for the pollutants listed below. All sampling shall take place on days representative of normal operations. All samples shall be taken within a two-week period, unless this is not feasible. Sampling shall be conducted in accordance with 40 C.F.R. § 403.12(b)(5)(iii), which states: “A minimum of four (4) grab samples must be used for pH, cyanide, total phenols, oil and grease, sulfide, and volatile organics. For all other pollutants, 24-hour composite samples must be obtained through flow-proportional composite sampling techniques where feasible. The [Department] may waive flow-proportional composite sampling for any Industrial User that demonstrates that flow-proportional sampling is infeasible. In such cases, samples may be obtained through time-proportional composite sampling techniques or through a minimum of four (4) grab samples where the User demonstrates that this will provide a representative sample of the effluent being discharged.” If this is infeasible, e.g., where the industrial user batch discharges, then the company must state how they will take representative samples.

Sample Pollutant Frequency Sample Type Location

Toxic Organics Of Concern ‘

1) Volatile Organics (VOC) Ml Once every 4 grab samples per day, taken at least 1 hour six-month apart for 4 days. Each sample must be monitoring individually preserved and sent to a certified period. laboratory. The laboratory may then composite each day's 4 grabs to make a daily composite for each of the 4 days. See Part 11, Sect. C(l). II II 2) Semi-volatile Organics Ml 4 one-day composite samples. See Part II, Sect. C(l).

Other Pollutants and pH II II Copper Ml 4 one-day composite samples. II II II II Cadmium Ml II II II II Chromium(Hexavalent)^ Ml II II II II Chromium (Total) Ml II II II Lead Ml

II II II II Nickel Ml

1-4

CITY_21MC100_006712700

NYC-WTC_000349278

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000349278Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000165900 · Box 7DDC

Document page containing contact details for Con Edison and JWC Environmental Health & Safety personnel.

Similar indexed content

Compare copies and versions →