Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 'aceAnalyticar Minneapo'is, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444

PROJECT; PCDD/PCDF ANALYSES DATE: April 4, 2002

PAGE: 2 REPORT NO: 02-1054762

PCDD/PCDF Analyte Enrichment

The extraction procedure often removes a variety of compounds, in addition to the PCDDs and PCDFs, from the sample matrix. Some of these compounds can directly interfere v\rith the analyses while others can overload the capillary column causing degradation in chromatographic resolution or sensitivity. The analyte enrichment steps described below are used to remove interferences from the extracts.

The extract was diluted to 100 mL with hexane, transferred to a separatory funnel, and washed with IN sodium hydroxide, concentrated sulfuric acid, and aqueous sodium chloride (5% w/v) as needed. The hexane extract was quantitatively transferred to a liquid chromatography column containing alternating layers of silica gel, 40% concentrated sulfuric acid on silica gel, and 33% 1 N sodium hydroxide on silica gel. The column was eluted with 90 mL of hexane and the entire eluate was collected and concentrated, under ambient conditions, to a volume of 1 mL.

The extract was then fractionated on a liquid chromatography column containing 4 g of activated alumina. The column was eluted with 20 mL of hexane followed by 1 5 mL of 60% methylene chloride/hexane. The 60% methylene chloride/hexane fraction was concentrated under a stream of dry nitrogen, spiked with recovery standards (1,2,3,4-TCDD-^^Ci2 and 1,2,3,7,8,9-HxCDD-^^Ci2) and taken to a final volume of 20 uL.

PCDD/PCDF Analyses

The sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced directly into the ion source of the mass spectrometer, thus providing the highest possible sensitivity while minimizing degradation of the chromatographic resolution.

REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.

nelac CITY_21MC100_003012796

NYC-WTC_000348995

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348995Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

No available related records indexed in this group.

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →