NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
10 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗Thirty-page analytical report from Pace Analytical Services containing environmental test results for project number 19125-0297.
NYC-WTC_000237148–000237177OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
Pace Analytical Services, Inc. 1700 Elm Street, Suite. 200 ^ace Analyticar Minrteapolis, MN 55414 Phone: 612.607.1700 www.pacelabs.com REPORT OF: CHEMICAL ANALYSES Fax: 612.607.6444
' PROJECT: PCDD/PCDF Analyses DATE: January 9, 2002
PAGE: 2 REPORT NO: 01-1052540
- PCDD/PCDF Analyte Enrichment
IT The extraction procedure often removes a variety of compounds, in addition to the PCDDs and PCDFs, from the sample matrix. Some of these compounds can directly interfere with the analyses while others can overload the capillary column causing degradation in chromatographic resolution ® or sensitivity. The analyte enrichment steps described below are used to remove interferences from the extracts.
Each extract was diluted to 100 mL with hexane, transferred to a separatory funnel, and washed with IN sodium hydroxide, concentrated sulfuric acid, and aqueous sodium chloride (5% w/v) as needed. The hexane extract was quantitatively transferred to a liquid chromatography column containing alternating layers of silica gel, 40% concentrated sulfuric acid on silica ^el, and 33% 1 N sodium hydroxide on silica gel. The column was eluted with 90 mL of hexane and the entire eluate was collected and concentrated, under ambient conditions, to a volume of 1 mL. LU
. Each extract was then fractionated on a liquid chromatography column containing 4 g of activated alumina. The column was eluted with 20 mL of hexane followed by 15 mL of 60% methylene chloride/hexane. The 60% methylene chloride/hexane fraction was concentrated to 1 mL under a ; J stream of dry nitrogen and applied to the top of a chromatography column containing 1 g of 5% . AX-21 activated carbon in silica gel. The column was eluted with two 2-mL portions of hexane, 2 mL of cyclohexane/methylene chloride (50:50 v/v) and cyclohexane/methanol/toluene (75:20:5 v/v) in the forward direction, and then with toluene in the reverse direction. The toluene fraction was collected, concentrated, spiked with recovery standards (1,2,3,4-TCDD-’^Ci2 and 1,2,3,7,8,9-. HxCDD-^2Gi2) and taken to a final volume of 20 uL.
a . • PCDD/PCDF Analyses
1 ES Each sample extract was analyzed for the presence of PCDDs and PCDFs using combined capillary column gas chromatography/high resolution mass spectrometry (HRGC/HRMS). The instrumentation consisted of a Hewlett Packard Model 6890 gas chromatograph interfaced to a Micromass Ultima high-resolution mass spectrometer. The capillary column was interfaced directly into the ion source of the mass spectrometer, thus providing the highest possible sensitivity while minimizing degradation of the chromatographic resolution.
REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc. vK ACCo,
CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660295
NYC-WTC_000237150
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
10 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272110
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
10 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226903
Pace Analytical laboratory report containing 25 pages of analytical results for samples collected at a New York City school.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400801
Pace Analytical lab report, 24 pages, Project [name], ATC 19125-0246; lab analysis details.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400723
PACE lab report; 30 pages, NELAC standards, project 19125-0246.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400775
Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.
10 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317124
Lab report for PCDD/PCDF levels with 17 pages prepared for ATC, Oct 2002.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317137
Lab report of PCDD/PCDF analyses for ATC Associates, Oct 2002.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000250132
Determination of PCDD/PCDF levels for ATC client at 104 East 25th Street.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000300414
Report of PCDD/PCDF determinations for ATC project; laboratory details and client info on file.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375724
Laboratory results for project 19125-0289 with PGDD/PCDF determinations, 21 pages.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000375748
Laboratory analysis report for ATC project, TEM/analysis, 21 pages.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400852
Pace Analytical lab report; project [name]; 19125-0246; 22 pages; general analysis.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000326628
Analytical lab report for PCDDs & PCDFs; city file reference.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similar indexed content
NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
Similar indexed content
NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
Similar indexed content
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
Similar indexed content
NYC-WTC_000226903
Pace Analytical laboratory report containing 25 pages of analytical results for samples collected at a New York City school.
Similar indexed content