Pace Analytical Services, Inc. 1700 Elm Street, Suite 200 weAnsilyticar www.pacelabs.com ReOrT OF: CHEMICAL ANALYSES Minneapolis, MM 55414 Pnone^ 612.607.1700 Fax: 612.607.6444
I PROJECT: PCDD/PCPF g^NALYSES PATE: January 9, 2002
PAGE: 3 REPORT NO: 01-1052540
PCDD/PCPF Analyses (Cont.)
The mass spectrometer was operated in the electron impact ionization mode at a mass resolution ! of 10,000-11,000 (M/AM, 10 percent valley definition). This resolution is sufficient to resolve most interferences, such as PCBs, thus providing the highest level of confidence that the detected { levels of PCDD/PCDF were not false positives resulting from interferences. Typical operating parameters for the HRGC/HRMS analyses are summarized in Table 2.
; ' The data were acquired by selected-ion-recording (SIR) using groups of ion masses similar to those - described in USEPA Method 8290. The five groups corresponded to the tetrachlorinated through octachlorinated congener classes. Each group contained tvvo ion masses for the PCDDs, two ion masses for the PCDFs, the corresponding ion masses from the two isotopically labeled internal ‘ standards, and the ion mass characteristic of the polychlorinated diphenylether (PCDE) which, if present, could cause false responses in the dibenzofuran channels. r/i - Each group of ion masses also contained a lock mass which was used by the data system to J automatically correct the mass focus of the instrument. The data system determined the centroid l{ of the lock mass during each data acquisition cycle and corrected the mass focus of the analyte and internal standard ion masses to assure that the centers of the mass peaks were being > monitored.
The criteria used to judge positive responses for a PCDD/PCDF isomer included:
* Simultaneous response at both ion masses of the PCDD or PCDF a * Signal-to-noise ratio equal to or greater than 2.5:1.0 for both ion masses * Chlorine isotope ratio within 15% of the theoretical value i * Chromatographic retention time within -l- /- 2 seconds of the expected retention time * Chromatographic retention times within elution windows determined from analyses of standard mixtures * Absence of simultaneous response in the PCDF and PCDPE ion traces
A list of the exact ion masses monitored for the determination of PCDD/PCDF isomers and the PCDE interferences is presented in Table 3. Also included are the theoretical chlorine isotope ratios for the ten congener classes.
/a REPORT OF LABORATORY ANALYSIS This report shall not be reproduced, except in full, without the written consent of Pace Analytical Services, Inc.
J .neiac CONFIDENTIAL, SUBJECT TO PROTECTIVE ORDER NO. 2, SEPT. 2008 CITY_21 MC100_014660296
NYC-WTC_000237151
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
No available related records indexed in this group.
NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
10 shared non-person entities · 1 shared topics · similarity 0.998
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000272110
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
10 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000226903
Pace Analytical laboratory report containing 25 pages of analytical results for samples collected at a New York City school.
9 shared non-person entities · 1 shared topics · similarity 0.995
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400801
Pace Analytical lab report, 24 pages, Project [name], ATC 19125-0246; lab analysis details.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400723
PACE lab report; 30 pages, NELAC standards, project 19125-0246.
11 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400775
Pace Analytical report with 23 pages; chemistry/NELAC standards; project ID partially visible.
10 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317124
Lab report for PCDD/PCDF levels with 17 pages prepared for ATC, Oct 2002.
7 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000317137
Lab report of PCDD/PCDF analyses for ATC Associates, Oct 2002.
5 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
9 shared non-person entities · 1 shared topics · similarity 0.994
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000400694
Pace Analytical lab report; project 19125-0246, 23 pages.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000399532
Laboratory analysis report for PCDD/PCDF on ATC project 19125-0279, 104 East 25th Street.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000383373
PACE lab report for ATC project 19125-0297; overview of method 8290.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000240242
Determination of dioxin and furan levels prepared for ATC Associates in New York, 2002.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348993
Determination of PCDD/PCDF levels for project: World Trade Center.
Similarity score 0.997 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
NYC-WTC_000249257
PACE Analytical report on PCDD/PCDF analyses submitted by ATC, Jan 2002.
Similar indexed content
NYC-WTC_000226877
Pace Analytical laboratory report detailing polychlorinated dibenzo-p-dioxin and dibenzofuran levels in samples from a NYC school.
Similar indexed content
NYC-WTC_000182790
Laboratory determination report for polychlorinated dibenzo-p-dioxins and furans from samples collected in late 2001.
Similar indexed content
Laboratory analysis report from Pace Analytical for a site sample related to the Education Department project.
Similar indexed content
NYC-WTC_000226903
Pace Analytical laboratory report containing 25 pages of analytical results for samples collected at a New York City school.
Similar indexed content