Z Z
o WTC Indoor Air/Environments Monitoring - Sampling and Analytical Procedures For Background and Pilot Clean up Studies o
co
g
o Media Sampling Points
Analytical
Sampling Method Proposed Description Analytical Method Proposed “0
I Parameters c
o
o CT
o This is a micro vacuuming method. Three collocated samples will o'
Ca3 SeUlcd Dust Carpets, fabric furniture or Asbestos ASTM D 5755-95 ASTM D 5755-95 "0
be collected from each location.
OO Porous Soft drapery in areas of activity o
oo
tn surfaces (living rooms, family rooms) This is a micro vacuuming method. Three collocated samples will
Lead ASTM E 1973-99 SW-846 601 OB
be collected from each location. o
o
Asbestos ASTM D 6480-99 o
Wipe Samples ASTM D 6480-99 (wipe) c
3
Lead HUD Appendix 13.1 Wipe Samples CD
SW-846 601 OB 3
Horizontal surfaces of
Settled Dust Dioxins ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8290
tables or counters and bare
Non-porous
floors, ceilings and walls in PAHs ASTM D 6661-01 Wipe Samples ASTM 6661-01/SW-846 8270C
Hard
areas of activity (living
surfaces Total Dust HUD Appendix 13.1” Wipe Sample collected at one location per unit. No Formal Method (NIOSH 7500 Modified)
rooms, family rooms)
Silica, calcite,
HUD Appendix 13.1" Wipe Samples. All parameters will be collected on one wipe. NIOSH 7500 (XRD)
gypsum
MMVF ASTM D 6480-99 Samples will be combined with the asbestos sampling. EMSL MSD.0300
Air pump operated at lOL/min for 8 hours Io achieve the COPC PCM NIOSH 7400 followed by TEM AHERA
Asbestos NIOSH 7400
wkgroup detection limit method.
Air pump operated at lOL/min for 8 hours to achieve the COPC
Lead NIOSH 7300 SW-846 601 OB
wkgroup detection limit
SW-846 8270 (Analytical method with be
Air pump operated at 2L/min for 8 hours. Pilot Clean-up study only
PAHs NIOSH 5515 modified to achieve the COPC wkgroup detection
for worst case scenarios.
limit
Areas of known activity
Indoor Air
(living rooms, family rooms' Air pump operated at 25L/min for 35 hours. This modification is not
Dioxins TO-9 (Modified for indoor air) a proven method. To be conducted during the Pilot Clean-up study SW-846 8290
only for worst case scenarios.
Silica, calcite, Air pump operated at 2.5L/min for 8 hours to achieve the COPC
NIOSH 7500 NIOSH 7500 (XRD)
gypsum wkgroup detection limits
Assumed that it behaves the same as asbestos, samples will be
MMVF NIOSH 7400 EMSL MSD.0300
combined with the asbestos sampling.
Bulk samples will be collected from HVAC or AC window type unit
PLM NYS 198.1 followed by
Asbestos Bulk Sample filters, shaken into a plastic bag and transferred into the sample
TEM NYS 198.4
container.
o
(If the volume required is not attainable for all analysis, the sample
Lead Bulk Sample SW-846 601 OB
will be analyzed for asbestos only.
HVAC systems and AC
to units (collection of bulk dust (If the volume required is not attainable for all analysis, the sample
PAHs Bulk Sample SW-846 8270
Bulk Dust sample from the unit air will be analyzed for asbestos only.
S
O filters). Background (If the volume required is not attainable for all analysis, the sample
Dioxins Bulk Sample SW-846 8290
o study only. will be analyzed for asbestos only.
o
1 Silica, calcite, (If the volume required is not attainable for all analysis, the sample
o Bulk Sample NIOSH 7500 (XRD)
gypsum will be analyzed for asbestos only.
o
to (If the volume required is not attainable for all analysis, the sample
MMVF Bulk Sample PLM NYS 198.1/EMSL MSD.0300
will be analyzed for asbestos only.______________
O',
co
NOTE: •• Wipe samples for silica, calcite and gypsum will be collected using the HUD Appendix 13.1 method since no standardized method is available.
DRAFT
OCR can misread numbers and units. Confirm readings against the page image before using them.