NYC 9/11 Public Portal Document
W \CEQR MANUAL\ 3J-8 12/93
\
before drilling activities. Soil samples may be obtained surements indicate positive or inconclusive results, it is
by hand auguring if rig access is not available; however, recommended that representative confirmatory sampling
this requires the subsurface to be penetrable by the hand and laboratory analysis be performed. Lead dust may
auger and can only extend to limited depths. also be considered in some structures and on some paved
surfaces in building yards or surrounding streets. "Visible
Drilling and-subsurface sampling-equipment should signs of staining, pooling, or discharge of waste material
be decontaminated prior to-all Ailling efforts. The soil inside structures should be sampled based on the
boring and-monitoriHg well installation plan should suspected material. For example, suspected PCB-
address the proposed number of wells or borings; well or containing surface stains are assessed by performing wipe
boring depth; well specifications; split spoon-sampling samples, which are then analyzed in the laboratory (see
inteiv'al; organic ^apor screening and soil description below).
methods;—potential—aquifer—pemieability—testing—er
determination; well development techniques; handling 331.3. Constituents for Analysis and Analytic
and disposal of borehole cuttings and well development Methods
water;—and method of determining the groimdwater
The conclusions of the initial assessment and the
elevation.
results of any first stage sampling efforts geophysical er
soil gas surveys govern the selection of test compounds.
Although split spoon is the commonly used sam-
Common types of hazardous materials found in soil and
pling tool on a conventional drilling, ng, other tools may
groundwater on sites in the City are petroleum hydrocar
be used if they obtain appropriate results including
bons, VOCs, PCBs, polycyclic aromatic hydrocarbons
hvdropunch groundwater saTotgiiTig. temporary well
(PAHs), and lead and other heavy metals. However,
points, and screened augers. For example, the
where past uses indicate that additional compounds could
hydropunch groundwater sampling tool is a -relatively
be on-site and there is no evidence to suggest that they are
new device gaining wider use and-aceeptance that can be
not, a broader testing of sanpies for possible
used to obtain groundwater samples during a test boring
contaminants is recommended. The samples should be
program. The hydropunch tool can be used generally
analyzed by a laboratory accredited by the New York
anywhere a split-spoon sampler can be used including
State Department of Health's Environmental Laboratory
depths much greater than practical with a groundwater
Approval Program (ELAP).
probe. The hydropunch allows the acquisition of a
groundwater sample without the installation of a perma
nent monitoring well. The hydropunch requires relatively
The laboratory anal-vse.s of environmental samnle.s should
permeable geologic formations and wall not allow for the
be conducted according to the bolding time and Quality
determination of the groundwater flow direction, as will
Assurancc/Qnality Control fOA/OQ reouirement!
permanent monitoring wells.
NYSDEC Analytical Services Protocol (ASP) ujsing the
latest update since June 2000 (Appt^nebx 5). Reports
Testing Buildings and Structures. It is possible for
should provide the reduced deliverables a.s specified for
building structures to be contaminated with hazardous
ASP Category A deliverables, unless Category B data
materials. These materials could have been introduced in
deliverables are requested by DEP.
construction materials or discharged as a result of poor
operational practices on the part of an industrial occupant.
The document -ean be obtained from NYSDEC Bureau
Appropriate sampling techniques depend on the material
of 'Watershed Assessment- and Research, attention Mr.
of concern and the location of the contamination in or on
Larry-Bailey, telephone! (518) 457 7470.
the building. Wipe samples, bulk samples, air samples,
coring samples, or field measurement may be
appropriate in different situations.
EPA SW-846: Test Methods for Evaluating Solid Waste:
Physical/Chemical Methods. 3"^ edition. 4 volumes
Common building materials include asbestos-con
(Appendix 5). I-nformation foi^ obtaining official printed
taining thermal systems, surfacing and miscellaneous
c-opy of SW-846 Manual, to obtain CD ROM, to view the
materials, and lead land other metals') in painted surfaces.
manual and-its DraftT-VA-& IVB Update will be available
Under local law 76 (see Section 711.3, below) bulk
at- URL! http!//www:ep ZSW^846/sv»’846a.htm'The
samples of suspect asbestos-containing materials must be
waste-water and drinking water analytical methods are
collected by a professional certified by DEP or the New
provided hv the I IS EPA Office of Water. EPA Methods
York City Department of Health. Material containing
and guidelines for Analysis of Water. (Appendix 5Lftn
more than 1 percent asbestos is considered asbestos-
GD ROM---- Vei=sieH---- 3.---------General---- informatiog!
containing. If lead-based paint is suspected, an initial
l«tp!//www«pft;g©v/s9fewa£ef/fHetIieds/€df0fftbdHt—
field assessment can be performed using a portable X-ray
Qiriering information! NTIS, 1-703 -605 6000 or e mail at
fluorescence (XRF) detector. If the initial field mea-
[email protected] by order PB99- 500209INQ
CITY_21MC100_01 0211636
NYC-WTC_000348852
OCR can misread numbers and units. Confirm readings against the page image before using them.