NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 1 page

Soil sampling and contamination guidance, DEPT. of Environmental Protection, 1993

Machine-extracted title · confidence 32%

Guidance excerpt on soil sampling methods, decontamination, and lead dust considerations for subsurface investigations.

NYC-WTC_000348852
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NYC 9/11 Public Portal Document

W \CEQR MANUAL\ 3J-8 12/93 \ before drilling activities. Soil samples may be obtained surements indicate positive or inconclusive results, it is by hand auguring if rig access is not available; however, recommended that representative confirmatory sampling this requires the subsurface to be penetrable by the hand and laboratory analysis be performed. Lead dust may auger and can only extend to limited depths. also be considered in some structures and on some paved surfaces in building yards or surrounding streets. "Visible Drilling and-subsurface sampling-equipment should signs of staining, pooling, or discharge of waste material be decontaminated prior to-all Ailling efforts. The soil inside structures should be sampled based on the boring and-monitoriHg well installation plan should suspected material. For example, suspected PCB- address the proposed number of wells or borings; well or containing surface stains are assessed by performing wipe boring depth; well specifications; split spoon-sampling samples, which are then analyzed in the laboratory (see inteiv'al; organic ^apor screening and soil description below). methods;—potential—aquifer—pemieability—testing—er determination; well development techniques; handling 331.3. Constituents for Analysis and Analytic and disposal of borehole cuttings and well development Methods water;—and method of determining the groimdwater The conclusions of the initial assessment and the elevation. results of any first stage sampling efforts geophysical er soil gas surveys govern the selection of test compounds. Although split spoon is the commonly used sam- Common types of hazardous materials found in soil and pling tool on a conventional drilling, ng, other tools may groundwater on sites in the City are petroleum hydrocar­ be used if they obtain appropriate results including bons, VOCs, PCBs, polycyclic aromatic hydrocarbons hvdropunch groundwater saTotgiiTig. temporary well (PAHs), and lead and other heavy metals. However, points, and screened augers. For example, the where past uses indicate that additional compounds could hydropunch groundwater sampling tool is a -relatively be on-site and there is no evidence to suggest that they are new device gaining wider use and-aceeptance that can be not, a broader testing of sanpies for possible used to obtain groundwater samples during a test boring contaminants is recommended. The samples should be program. The hydropunch tool can be used generally analyzed by a laboratory accredited by the New York anywhere a split-spoon sampler can be used including State Department of Health's Environmental Laboratory depths much greater than practical with a groundwater Approval Program (ELAP). probe. The hydropunch allows the acquisition of a groundwater sample without the installation of a perma­ nent monitoring well. The hydropunch requires relatively The laboratory anal-vse.s of environmental samnle.s should permeable geologic formations and wall not allow for the be conducted according to the bolding time and Quality determination of the groundwater flow direction, as will Assurancc/Qnality Control fOA/OQ reouirement! permanent monitoring wells. NYSDEC Analytical Services Protocol (ASP) ujsing the latest update since June 2000 (Appt^nebx 5). Reports Testing Buildings and Structures. It is possible for should provide the reduced deliverables a.s specified for building structures to be contaminated with hazardous ASP Category A deliverables, unless Category B data materials. These materials could have been introduced in deliverables are requested by DEP. construction materials or discharged as a result of poor operational practices on the part of an industrial occupant. The document -ean be obtained from NYSDEC Bureau Appropriate sampling techniques depend on the material of 'Watershed Assessment- and Research, attention Mr. of concern and the location of the contamination in or on Larry-Bailey, telephone! (518) 457 7470. the building. Wipe samples, bulk samples, air samples, coring samples, or field measurement may be appropriate in different situations. EPA SW-846: Test Methods for Evaluating Solid Waste: Physical/Chemical Methods. 3"^ edition. 4 volumes Common building materials include asbestos-con­ (Appendix 5). I-nformation foi^ obtaining official printed taining thermal systems, surfacing and miscellaneous c-opy of SW-846 Manual, to obtain CD ROM, to view the materials, and lead land other metals') in painted surfaces. manual and-its DraftT-VA-& IVB Update will be available Under local law 76 (see Section 711.3, below) bulk at- URL! http!//www:ep ZSW^846/sv»’846a.htm'The samples of suspect asbestos-containing materials must be waste-water and drinking water analytical methods are collected by a professional certified by DEP or the New provided hv the I IS EPA Office of Water. EPA Methods York City Department of Health. Material containing and guidelines for Analysis of Water. (Appendix 5Lftn more than 1 percent asbestos is considered asbestos- GD ROM---- Vei=sieH---- 3.---------General---- informatiog! containing. If lead-based paint is suspected, an initial l«tp!//www«pft;g©v/s9fewa£ef/fHetIieds/€df0fftbdHt— field assessment can be performed using a portable X-ray Qiriering information! NTIS, 1-703 -605 6000 or e mail at fluorescence (XRF) detector. If the initial field mea- [email protected] by order PB99- 500209INQ

CITY_21MC100_01 0211636

NYC-WTC_000348852

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348852Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →