NYC Law Department release
Independent mirror · updated as the City releases more · v1.5.1
☕ Buy me a coffee
← Document results/Unboxed/No folder label
Document / 2 pages

Air sample analysis report, East 38th Street project, Mar 2003

Machine-extracted title · confidence 39%

Air sample analysis report for asbestos task force at East 38th Street project site, Mar 2003.

NYC-WTC_000348511–000348512
Page image
Page image not rendered yet.
The pipeline renders page images incrementally; check back or read the OCR text alongside.
OCR text

OCR status: ok · source: pdftotext

NICHE NICHE ANALYSIS, INC.

AIR SAMPLEANALYSISREPORT NICHE FILE: 03-1702-2 NEW YORK CITY - DEP ASBESTOS TASK FORCE 59-17 JUNCTION BOULEVARD, 11TH FLOOR FLUSHING, NEW YORK 11373-5108 PHONE : (718) 595-4384; FAX: (718) 595-4387 Page 1 of 1

WORK ORDER LTR. # ASB9-00-(Pending) COMP# Pending PROJECT NAME East 38th Street Water Maintenance CONTRACT REG. # CTC 826 20010014956 LOCATION Outside Garage by Pickup Truck DATE SAMPLED 03-14-03 PROJECT ADDRESS 3825 FDR Drive DATE RECEIVED 03-15-03 New York, NY DATE ANALYZED 03-15-03 Sample Lab No. Sample Sample Location Volume Results No. Type (liter) Fiber/CC 1 A0301384 Dur Outside bldg/ on 38th Street/ Rear of the Pickup car 1904 0.0033 Cleanup 2 A0301385 Dur Outside bldg/ on 38th Street/ Front of the Pickup 1904 0.0033 Cleanup car 3 A0301386 Dur Inside Garage/ Outside office/ by the entrance to 1853 0.005 Cleanup main office 4 A0301387 Dur Inside bldg/ Main office/ By Copy machine 1717 0.0017 Cleanup 5 A0301388 Field Blank 0 fiber/100 fields

6 A0301389 Field Blank 0 fiber/100 fields Note: NICHE is responsible for only the fiber counts within the limitations of the method described as NIOSH 7400. Among other limitations, this method gives only an index of airborne fibers and provides only an estimate of asbestos concentration Any and all claims arising out of NICHE'S analysis of these samples are limited in recovery to cost of analyzing samples. This report shall not be reproduced except in full, without the wriiten approval of NICHE. NICHE accepts no other liability and the client agrees to seek no costs beyond the above. •<LOD = less than limit of detection, which is 5.5 fibers per 100 fields in accordance with NIOSH method 7400.

SAMPLE ANALYSIS BY: POSITIVE PHASE CONTRAST MICROSCOPY (PCM) METHOD OF SAMPLE PREPARATION & ANALYSIS; ALL SAMPLES WERE ANALYZED IN ACCORDANCE WITH THE NIOSH 7400 METHOD USING "A" COUNTING RULES. INSTRUMENT: E. LEITZ WETZLAR PCM-Nr,518599 WITH WALTON-BECKETT GRATICULE (100UM FIELD DIAMETER)

ELAP#: 11236

BING LIANG Bing Liang Laboratory Director Field Technician pproved Signatory c CD E 3 o o Q TO ■c o co Q_ o co o Z o 3 o 0. o'

o 6 z z 10 Fiske Place, Suite 517, Mount Vernon, NY 10550 • Phone: (914) 663-8937 • Fax: (914) 663-8782

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348511Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

NYC-WTC_000343109

Niche Analysis, Inc. air sample report for a New York client.

Similar indexed content

Compare copies and versions →