« a JB JB SciLabJob#: 201093489 Page 3 of 3 Client Name; Independent Monitoring & Analysis, Inc. Phase Contrast Microscopy (PCM) Fiber Results 250 Broadway Building Assoc.; 250 Broadway, NYC, Various Floors / Pre-Air Sampling Flow Air Fiber Fibers SciLab Client riate Duration Filtered Density Cone, Fields Fibers TWA Sample # Sample # / Location Collected (liters/min.) (min.) (liters) (Fibers/mm ) (Fibers/cc)

31 31 9/28/2001 15 80 1200 100 3 3.82 < 0.002 Building Associates Management Office 32 32 9/28/1001 15 80 1200 100 2 2.55 < 0.002 Building Management Conference Room 33 33 9/28/2001 15 80 1200 100 2 2.55 < 0.002 Northwest End of 30th Floor 34 34 9/28/2001 15 80 1200 100 2 2.55 < 0.002 Southeast End of 30th Floor 35 35 9/28/2001 15 80 1200 100 9 11.46 0.004 30th Floor Passenger Elevator 36 36 9/28/2001 0 0 0 100 0.5 0.64 Field Blank Footnotes: / 37 37 9/28/2001 0 0 0 100 0.5 0.64 Field Blank Footnotes: I Reporting Notes: (1) Fibers/cc cannot be calcuIatecLfor sam] :s) with no air volume. Analyzed by: Tatyana Grimchak Date Analyzed: 9/29/2001

Samples analyzed by NIOSH 7400(A) Method, Issue #2, 8/15/94; Limit of Dec(ection= 5.5 fibers per 100 fields or 7 fibers/mm2; This report relates ONLY to the sample analysis expressed as fibers/sq mm of filter area; ND = no fibers observed; NA =not analyzed; Walton-Beckett gradicule field area 0.00785 mini; TWA =8 Hr TWA calculation assumes zero exposure for remainder of 8 hr period not sampled; Upper 95% Confidence limit (Employers Compliance Test)- Calculated as a one sided UCL to determine 95% certainty of compliance with the 0.01 fiber/cc standard; Estimated relative standard deviation: Intralab Sr=0.405, Interlab Sr=0.45. New York samples (NYSDOH ELAP Lab # 11480); National Institute of Standards and Technology ATUA imQAI

Q H

IO

S o o o I o o co o o co co (JI C75

NYC-WTC_000348308

OCR can misread numbers and units. Confirm readings against the page image before using them.

NYC-WTC_000348308Source: NYC Law Department, mirrored locally

Related records

Browse subjects →

Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.

Same-box records

Filed elsewhere

More like this page

Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.

Others also read

Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.

Compare copies and versions →