NYC-WTC_000348210
DEP project sample dates late May 2002; 24-hour turnaround.
21 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗Air sample analysis report by Lab for Warren & Panzer Engineers; Phase Contrast Microscopy, May 17, 2002.
NYC-WTC_000348229–000348230OCR status: ok · source: pdftotext
NYC 9/11 Public Portal Document
228 East 45th Street
WKP 10th Floor New York, NY 10017 Tel: (212) 922-0689 LABORATORIES, INC Fax; (212)922-0630 AIR SAMPLE ANALYSIS REPORT PHASE CONTRAST MICROSCOPY
CLIENT: WARREN & PANZER ENGINEERS, P.C. TURNAROUND TIME 24HRS
WKP FILE # 501-01 SAMPLE DATE 5/17/2002
WKP LOG I.D. # N0205117, N0205118, and N0205119 RECEIVED DATE 5/17/2002
Contract #: WTC AR2 ANALYSIS DATE 5/17/2002
REPORT DATE 5/17/2002 CLIENT JOB: NYC Department of Environmental Protection CLIENT JOB #: 1079.01.01 LOCATION S.W. Area/ Site Map ANALYSIS: AIRBORNE FIBER COUNTING, PHASE CONTRAST MICROSCOPY, NIOSH 7400. NIOSH PAT Lab NO. 07186; NY COLLECTION DEVICE: 25 mm MCE Filter Cassette; Collection Area = 385 sq mm;
SAMPLE WERE COLLECTED BY: Warren and Panzer
SUMMARY OF ANALYSIS
CLIENT FIBERS/ FIBERS/ SAMPLE # Site# SAMPLE LOCATION Vol. sq mm cc
1079.01.01 001 27 Gateway Plaza Park Area 675 1.30 <0.004 002 31 South End Ave. and Albany Street 675 0.00 <0.004 003 32 West Street and Albany Place 675 1.30 <0.004 004 33A Rector Place by the Park Place 675 0.00 <0.004 005 34 W. Thames Street - Along Waterfront 675 0.00 <0.004 006 37 West of Third Place 675 2.50 <0.004 007 8 West Street and Warren Street 675 3.80 <0.004 008 4 River Terrace and Chambers Street 675 1.30 <0.004 009 6A River Terrace Park Area Between Park Place and Warren Street 675 0.00 <0.004 010 9 River Terrace and Park Place West 675 1.30 <0.004 oil 17 River Terrace and Vesey 675 6.30 <0.004 012 7 Warren Street and North End Avenue 675 8.90 0.005 013 10 North End Avenue Park place West 675 1.30 <0.004 014 29 Trinity Place and Thames Street 675 1.30 <0.004 015 21 Fulton and Church Street 675 1.30 <0.004 016 20A Vesey Street and West Broadway 675 2.50 <0.004 017 16 Park place and Church Street 675 1.30 <0.004 018 12 Murray Street and Church Street 675 0.00 <0.004 019 15 Park Place and Greenwich Street 675 0.00 <0.004 020 11 Murray Street and Greenwich Street 675 0.00 <0.004 021 Field Blank 0.00 022 Field Blank 0.00
NOTES: 1.5.5 fibers/100 fields was used to calculate the limit of detection (LOD). 2. Samples were not collected by WKP Laboratories, Inc. 3. The Federal EPA Clearance Critical following an asbestos abatement project is 0.010 fibers/cc. 4. PCM air samples will be disposed of after 3 months unless otherwise directed by client in writing.
u-LL L.L.
LABORATORY ANALYST LABORATORY DIRECTOR
CITY_21MC100_003005444
NYC-WTC_000348229
OCR can misread numbers and units. Confirm readings against the page image before using them.
Ranked by indexed similarity. Reasons describe shared subjects and filing context; check the source records.
NYC-WTC_000348210
DEP project sample dates late May 2002; 24-hour turnaround.
21 shared non-person entities · 1 shared topics · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161747
Chain-of-custody form and monitoring log sheet for air samples collected at the World Trade Center site.
21 shared non-person entities · similarity 0.951
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161810
Phase contrast microscopy report for airborne fiber counting at the World Trade Center site dated May 2002.
20 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000161786
Laboratory report detailing phase contrast microscopy results for airborne fiber counting in the southwest area of the World Trade Center site dated April 16, 2002.
21 shared non-person entities · similarity 0.945
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109724
Form recording facade inspection results for the building at 228 West Broadway.
1 shared non-person entities · similarity 0.943
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109719
Form recording facade inspection results for the building at 226 West Broadway.
1 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109699
Building assessment form recording facade conditions and debris measurements for 211 West Broadway.
1 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000109729
Form recording facade inspection results for the building at 229 West Broadway.
1 shared non-person entities · similarity 0.940
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000110103
Inspection form documenting visual survey results for facade and ACM conditions at 8 White Street following the World Trade Center collapse.
1 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000110118
Form recording visual facade inspection results and ACM presence at 11 White Street in October 2001.
1 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000110113
Inspection form recording facade condition and hazardous material survey results for 12 White Street.
1 shared non-person entities · similarity 0.939
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000130673
Inspection form for 112 Franklin Street recording facade condition results including ACM and air monitoring data.
1 shared non-person entities · similarity 0.938
machine-extracted · confidence unavailable · Check page ↗Similar subjects in other documents. Similarity does not establish the same event, measurement or conclusion.
NYC-WTC_000348082
Air sample analysis for NYC DEP; Phase Contrast Microscopy.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348110
Air sample analysis for Warren & Panzer, 6/27/02, NYC DEP project.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348081
Air sample analysis; Phase Contrast Microscopy, 7/4/02 date
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348104
Air sample analysis report using phase contrast microscopy for NYC DEP project, Warren & Panzer, dated 6/29/02.
Similarity score 0.999 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348175
Lab report for Warren & Panzer; Phase Contrast Microscopy and NIOSH 7400.
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗NYC-WTC_000348145
Phase contrast microscopy analysis of air samples for W&P at NYC site (6/2002).
Similarity score 0.998 (not a probability)
machine-extracted · confidence unavailable · Check page ↗Machine-extracted building matches; verify each source. Buildings, never households.
Readers open these alongside this record — through an Ask answer, the same folder, or indexed similarity. Not a claim they are about the same event.
Chain-of-custody form and monitoring log sheet for air samples collected at the World Trade Center site.
Similar indexed content
Phase contrast microscopy report for airborne fiber counting at the World Trade Center site dated May 2002.
Similar indexed content
Laboratory report detailing phase contrast microscopy results for airborne fiber counting in the southwest area of the World Trade Center site dated April 16, 2002.
Similar indexed content
Form recording facade inspection results for the building at 228 West Broadway.
Similar indexed content
Form recording facade inspection results for the building at 226 West Broadway.
Similar indexed content